Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
The VND600PEP-E is a monolithic device made using STMicroelectronics VIPower M0-3 technology. It is intended for driving resistive or inductive loads with one side connected to ground. Active VCC pin voltage clamp protects the device against low energy spikes (see ISO7637 transient compatibility table).
This device has two channels in high side configuration; each channel has an analog sense output on which the sensing current is proportional (according to a known ratio) to the corresponding load current. Built-in thermal shut-down and outputs current limitation protect the chip from over temperature and short circuit. Device turns off in case of ground pin disconnection.
VND600PEP-E Maximum Ratings
Symbol
Parameter
Value
Unit
VCC
-VCC
- IGND
DC supply voltage
Reverse supply voltage
DC reverse ground pin current
41
-0.3
-200
V
V
mA
IOUT
IR
IIN
Output current
Reverse output current
Input current
Internally limited
-21
+/- 10
A
A
mA
VCSENSE
Current sense maximum voltage
-3 +15
V V
VESD
Electrostatic Discharge (Human Body Model: R=1.5K; C=100pF) - INPUT
- CURRENT SENSE
- OUTPUT
- VCC
4000
2000
5000
5000
V
V
V
V
EMAX
Maximum Switching Energy (L=0.13mH; RL=0; Vbat=13.5V; Tjstart=150; IL=40A)
146
mJ
Ptot
Tj
Power dissipation at Tc=25
Junction operating temperature
96
Internally limited
W
Tc
TSTG
Case operating temperature
Storage temperature
-40 to 150
-55 to 150
VND600PEP-E Features
DC SHORT CIRCUIT CURRENT: 25A CMOS COMPATIBLE INPUTS PROPORTIONAL LOAD CURRENT SENSE UNDERVOLTAGE AND OVERVOLTAGE SHUT-DOWN OVERVOLTAGE CLAMP THERMAL SHUT-DOWN CURRENT LIMITATION VERY LOW STAND-BY POWER DISSIPATION PROTECTION AGAINST: LOSS OF GROUND AND LOSS OF VCC REVERSE BATTERY PROTECTION (**) IN COMPLIANCE WITH THE 2002/95/EC EUROPEAN DIRECTIVE