UGF10FCT, UGF10G, UGF10GCT Selling Leads, Datasheet
MFG:GS Package Cooled:9800 D/C:TO
UGF10FCT, UGF10G, UGF10GCT Datasheet download
Part Number: UGF10FCT
MFG: GS
Package Cooled: 9800
D/C: TO
MFG:GS Package Cooled:9800 D/C:TO
UGF10FCT, UGF10G, UGF10GCT Datasheet download
MFG: GS
Package Cooled: 9800
D/C: TO
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: UGF10FCT
File Size: 87553 KB
Manufacturer: GE [General Semiconductor]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: UGF10G
File Size: 63521 KB
Manufacturer: ZOWIE [Zowie Technology Corporation]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: UGF10GCT
File Size: 87553 KB
Manufacturer: GE [General Semiconductor]
Download : Click here to Download
SYMBOLS |
UGF8FT |
UGF8GT |
UNITS | |
Maximum repetitive peak reverse voltage |
VRRM |
300 |
400 |
Volts |
Working peak reverse voltage |
VRWM |
225 |
300 |
Volts |
Maximum RMS voltage |
VRMS |
210 |
280 |
Volts |
Maximum DC blocking voltage |
VDC |
300 |
400 |
Volts |
Maximum average forward rectified current at TC=100°C |
I(AV) |
10 |
Amps | |
Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method)per leg |
IFSM |
69A |
Amps | |
Maximum instantaneous forward voltage per leg TJ=25°C IF= 5A TJ=150°C |
VF |
1.30 1.05 |
Volts | |
Maximum reverse leakage current at working peak reverse voltage |
IR |
10 200 |
A | |
Maximum reverse recovery time per leg at IF=0.5A, IR=1.0A, Irr=0.25A |
trr |
35 |
ns | |
Maximum Reverse recovery time per leg at IF=1.0A, di/dt=100A/ms, VR=30V, Irr=0.1 IRM |
trr |
50 |
ns | |
Maximum reverse recovery current per legat IF=5A, di/dt=50A/ms,VR=30V |
IRM |
3.0 |
Amps | |
Maximum stored charge per leg IF=2A, di/dt=20A/ms, VR=30V, Irr=0.1IRM |
Qrr |
50 |
nC | |
Typical thermal resistance from junction to case per leg |
RQJC |
6.0 |
°C/W | |
Operating junction and storage temperature range |
TJ, TSTG |
-40 to+150 |
°C |
SYMBOLS |
UGF8FT |
UGF8GT |
UNITS | |
Maximum repetitive peak reverse voltage |
VRRM |
300 |
400 |
Volts |
Working peak reverse voltage |
VRWM |
225 |
300 |
Volts |
Maximum RMS voltage |
VRMS |
210 |
280 |
Volts |
Maximum DC blocking voltage |
VDC |
300 |
400 |
Volts |
Maximum average forward rectified current at TC=100°C |
I(AV) |
10 |
Amps | |
Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method)per leg |
IFSM |
69A |
Amps | |
Maximum instantaneous forward voltage per leg TJ=25°C IF= 5A TJ=150°C |
VF |
1.30 1.05 |
Volts | |
Maximum reverse leakage current at working peak reverse voltage |
IR |
10 200 |
A | |
Maximum reverse recovery time per leg at IF=0.5A, IR=1.0A, Irr=0.25A |
trr |
35 |
ns | |
Maximum Reverse recovery time per leg at IF=1.0A, di/dt=100A/ms, VR=30V, Irr=0.1 IRM |
trr |
50 |
ns | |
Maximum reverse recovery current per legat IF=5A, di/dt=50A/ms,VR=30V |
IRM |
3.0 |
Amps | |
Maximum stored charge per leg IF=2A, di/dt=20A/ms, VR=30V, Irr=0.1IRM |
Qrr |
50 |
nC | |
Typical thermal resistance from junction to case per leg |
RQJC |
6.0 |
°C/W | |
Operating junction and storage temperature range |
TJ, TSTG |
-40 to+150 |
°C |