UGF10A, UGF10ACT, UGF10B Selling Leads, Datasheet
MFG:VIS Package Cooled:9800 D/C:09+
UGF10A, UGF10ACT, UGF10B Datasheet download
Part Number: UGF10A
MFG: VIS
Package Cooled: 9800
D/C: 09+
MFG:VIS Package Cooled:9800 D/C:09+
UGF10A, UGF10ACT, UGF10B Datasheet download
MFG: VIS
Package Cooled: 9800
D/C: 09+
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: UGF10A
File Size: 63521 KB
Manufacturer: ZOWIE [Zowie Technology Corporation]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: UGF10ACT
File Size: 87668 KB
Manufacturer: GE [General Semiconductor]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: UGF10B
File Size: 63521 KB
Manufacturer: ZOWIE [Zowie Technology Corporation]
Download : Click here to Download
SYMBOLS |
UGF10ACT |
UGF10BCT |
UGF10CCT |
UGF10DCT |
UNITS | |
Maximum repetitive peak reverse voltage |
VRRM |
50 |
100 |
150 |
200 |
Volts |
Working peak reverse voltage |
VRWM |
50 |
100 |
150 |
200 |
Volts |
Maximum RMS voltage |
VRMS |
35 |
70 |
105 |
140 |
Volts |
Maximum DC blocking voltage |
VDC |
100 |
100 |
200 |
200 |
Volts |
Maximum average forward rectified current at TC=100°C |
I(AV) |
10 |
Amps | |||
Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method) per leg |
IFSM |
60 |
Amps | |||
Maximum instantaneous forward voltage per leg at IF=10A,TJ=25°C IF=5A, TJ=25°C IF=5A, TJ=150°C |
VF |
1.25 1.10 0.895 |
Volls | |||
Maximum reverse leakage current per leg TJ=25°C at working peak reverse voltage TJ=100°C |
IR |
10 200 |
A | |||
Maximum reverse recovery time per leg at IF=1.0A, di/dt=100A/ms, VR=30V, Irr=0.1 IRM |
trr |
25 |
ns | |||
Maximum reverse recovery time per leg at Maximum IF=0.5A, IR=1.0A, Irr=0.25A Typical |
trr |
25 15 |
ns | |||
Maximum reverse recovery current per leg at IF=5A, di/dt=50A/ms,VR=30V |
IRM |
0.7 |
Amps | |||
Maximum stored charge per leg Maximum IF=2A, di/dt=20A/ms, VR=30V Irr=0.1 IRM Typical |
Qrr |
5.5 4.5 |
nC | |||
Typical thermal resistance from junction to case per leg |
RQJC |
6.0 |
°C/W | |||
Operating junction and storage temperature range |
TJ, TSTG |
-40 to +150 |
°C |