Features: • 43A, 250V, rDS(ON) = 0.047• UIS Rated• Total Dose- Meets Pre-RAD Specifications to 100K RAD (Si)- Rated to 300K RAD (Si)• Single Event- Safe Operating Area Curve for Single Event Effects- SEE Immunity for LET of 36MeV/mg/cm2 with VDS up to 100% of Rated Breakdow...
FSPJ264F: Features: • 43A, 250V, rDS(ON) = 0.047• UIS Rated• Total Dose- Meets Pre-RAD Specifications to 100K RAD (Si)- Rated to 300K RAD (Si)• Single Event- Safe Operating Area Curve ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Drain to Source Voltage | VDS | 250 | V |
Drain to Gate Voltage (RGS = 20W) | VDGR | 250 | V |
Continuous Drain Current TC = 25oC |
ID | 43 | A |
TC = 100oC. | ID | 27 | A |
Pulsed Drain Current | IDM | 160 | A |
Pulsed Drain Current | VGS | ±30 | V |
Maximum Power Dissipation TC = 25oC |
PT | 192 | W |
TC = 100oC | PT | 77 | W |
Linear Derating Factor | 1.54 | W/oC | |
Single Pulsed Avalanche Current, L = 100mH, (See Test Figure) | IAS | 85 | A |
Continuous Source Current (Body Diode) | IS | 43 | A |
Pulsed Source Current (Body Diode) | ISM | 160 | A |
Operating and Storage Temperature | TJ, TSTG | -55 to 150 | |
Lead Temperature (During Soldering) | TL | 300 | |
(Distance >0.063in (1.6mm) from Case, 10s Max) Weight (Typical) |
9.3(Typical) | g |