Features: · High differential or common-mode input voltage ranges of +7V on the DS26LS32· +0.2 sensitivity over the input voltage range on the DS26LS32· Input fail-safe circuitry on the DS26LS32A.· DS26LS32 meet all requirements of RS-422 and RS-423· 6k minimum input impedance· 100 mV input hyster...
MNDS26LS32-X: Features: · High differential or common-mode input voltage ranges of +7V on the DS26LS32· +0.2 sensitivity over the input voltage range on the DS26LS32· Input fail-safe circuitry on the DS26LS32A.· ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: ·Fast rise and fall times-20 ns 1000 pF load·High output swing-20V·High output current d...
Features: · Meets EIA Standard RS-422A and RS-485· Meets SCSI specifications· Designed for multipo...
Features: ·Meets EIA Standard RS-422A and RS-485·Meets SCSI specifications·Designed for multipoint...
Supply Voltage.......................................................7V
Common-Mode Range.......................................+ 25V
Differential Input Voltage..................................+ 25V
Enable Voltage.......................................................7V
Output Sink Current.........................................50 mA
Maximum Power Dissipation at 25C
(Note 2)
J package ................................................1666.5 mW
E package ..................................................1875 mW
W package ..............................................967.74 mW
Storage Temperature Range...............-65C to +165C
Lead Temperature (Soldering, 4 Seconds).........260C
Note 1: "Absolute Maximum Rating" are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the device should be operated at these limits. The table of "Electrical Characteristics" provide conditions for actual device operation.
Note 2: Derate J package 11.11 mW/C above 25C; derate E package 12.5 mW/C above 25C. Derate W package: 6.4516 mW/C above 25C.
The DS26LS32 and DS26LS32A are quad differential line receivers designed to meet the RS-422, RS-423 and Federal Standards 1020 and 1030 for balanced and unbalanced digital data transmission.
The DS26LS32 and DS26LS32A have and input sensitivity of 200 mV over the input voltage range of + 7V and the DS26LS33 and DS26LS33A have an input senssitivity of 500 mV over the input voltage range of + 15V.
Both the DS26LS32A and DS26LS33A differ in function from the popular DS26LS32 and DS26LS33 in that input pull-up and pull-down resistors are included which prevent output oscillation on unused channels.Each version provides an enable and disable function common to all four receivers and features TRI-STATE outputs with 8mA sink capability. Constructed using low power Schottky processing, these devices are available over the full military and commerical operating temperature ranges.