DescriptionThe following cumulative test results have been obtained from testing performed at Hewlett- Packard in accordance with the ATF-10XXX ATF-13XXX latest revision of MIL-STD-883. Data was gathered from the product qualification, reliability monitor, and engineering evaluation for the LYG Ga...
ATF-10XXX: DescriptionThe following cumulative test results have been obtained from testing performed at Hewlett- Packard in accordance with the ATF-10XXX ATF-13XXX latest revision of MIL-STD-883. Data was gat...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The following cumulative test results have been obtained from testing performed at Hewlett- Packard in accordance with the ATF-10XXX ATF-13XXX latest revision of MIL-STD-883. Data was gathered from the product qualification, reliability monitor, and engineering evaluation for the LYG GaAs process.
For the purpose of this ATF-10XXX reliability data sheet, a failure is any part which fails to meet the electrical and/or mechanical specification listed in the Communications Components Designer's Catalog.