Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
The LOG102 is a versatile integrated circuit that computes the logarithm or log ratio of an input current relative to a reference current.
The LOG102 is tested over a wide dynamic range of input signals. In log ratio applications, a signal current can be generated by a photodiode, and a reference current from a resistor in series with a precision external voltage reference.
A3 and A4 are identical, uncommitted op amps that can be used for a variety of functions, such as filtering, offsetting, adding gain or as a comparator to detect loss of signal.
The output signal at VLOG OUT is trimmed to 1V per decade of input current. It can be scaled with an output amplifier, either A3 or A4.
Low dc offset voltage and temperature drift allow accurate measurement of low-level signals over a wide environmental temperature range. The LOG102 is specified over the temperature range, 0°C to +70, with operation over 40 to +85.
LOG102 Maximum Ratings
Supply Voltage, V+ to V ...................................... 36V Input Voltage .......................... V (0.5) to V+ (+0.5V) Input Current .................................................... ±10mA Output Short-Circuit(2) ................................ Continuous Operating Temperature ..........................40 to +85 Storage Temperature ............................55 to +125 Junction Temperature .......................................... +150 Lead Temperature (soldering, 10s) .......................+300
LOG102 Features
· EASY-TO-USE COMPLETE LOG RATIO FUNCTION · OUTPUT AMPLIFIERS FOR SCALING AND SIGNAL LOSS INDICATION · HIGH ACCURACY: 0.15% FSO Total Error Over 6 Decades · WIDE INPUT DYNAMIC RANGE: 6 Decades, 1nA to 1mA · LOW QUIESCENT CURRENT: 1.25mA · SO-14 PACKAGE
LOG102 Typical Application
· ONET, OPTICAL POWER METERS · LOG, LOG RATIO COMPUTATION: Communication, Analytical, Medical, Industrial, Test, General Instrumentation · PHOTODIODE SIGNAL COMPRESSION AMP · ANALOG SIGNAL COMPRESSION IN FRONT OF A/D CONVERTER · ABSORBANCE MEASUREMENT · OPTICAL DENSITY MEASUREMENT