Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: FRH20A15
File Size: 47921 KB
Manufacturer: NIEC [Nihon Inter Electronics Corporation]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: FRH20A20
File Size: 83367 KB
Manufacturer: NIEC [Nihon Inter Electronics Corporation]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: FR-159
File Size: 39518 KB
Manufacturer: ETC [ETC]
Download : Click here to Download
Rating | Symbol | FRH20A15 | Unit | ||
Repetitive Peak Reverse Voltage | VRRM | 150 | V | ||
Average Rectified Output Current | IO | 20 | Tc=120 | 50Hz Full Sine Wave Resistive Load | A |
RMS Forward Current | IF(RMS) | 22.2 | A | ||
Surge Forward Current | IFSM | 180 | 50Hz Full Sine Wave,1cycle,Non-repetitive | A | |
Operating JunctionTemperature Range | Tjw | - 40 to + 150 | |||
Storage Temperature Range | Tstg | - 40 to + 150 | |||
Mounting torque | Ftor | recommended torque = 0.5 | N.m |
Rating | Symbol | FRH20A20 | Unit | ||
Repetitive Peak Reverse Voltage | VRRM | 200 | V | ||
Average Rectified Output Current | IO | 20 | Tc=118 | 50Hz Full Sine Wave Resistive Load | A |
RMS Forward Current | IF(RMS) | 22.2 | A | ||
Surge Forward Current | IFSM | 120 | 50Hz Full Sine Wave,1cycle,Non-repetitive | A | |
Operating JunctionTemperature Range | Tjw | - 40 to + 150 | |||
Storage Temperature Range | Tstg | - 40 to + 150 | |||
Mounting torque | Ftor | Recommended value = 0.5 | N.m |