BYV26, BYV26 EGP- E3/73, BYV26A.B.C.D.E Selling Leads, Datasheet
MFG:PHI Package Cooled:smd/dip D/C:N/A
BYV26, BYV26 EGP- E3/73, BYV26A.B.C.D.E Datasheet download
Part Number: BYV26
MFG: PHI
Package Cooled: smd/dip
D/C: N/A
MFG:PHI Package Cooled:smd/dip D/C:N/A
BYV26, BYV26 EGP- E3/73, BYV26A.B.C.D.E Datasheet download
MFG: PHI
Package Cooled: smd/dip
D/C: N/A
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: BYV26
File Size: 70873 KB
Manufacturer: VISAY [Vishay Siliconix]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: BYV 10- 40
File Size: 74687 KB
Manufacturer: STMicro
Download : Click here to Download
PDF/DataSheet Download
Datasheet: BYV 10- 40
File Size: 74687 KB
Manufacturer: STMicro
Download : Click here to Download
Rugged glass SOD57 package, using a high temperature alloyed construction.
This package is hermetically sealed and fatigue free as coefficients of expansion of all used parts are matched.
SYMBOL |
PARAMETER |
CONDITIONS |
MIN. |
MAX. |
UNIT |
VRRM |
repetitive peak reverse voltage |
- - - - - - - |
200 400 600 800 1000 1200 1400 |
V V V V V V V | |
VR |
continuous reverse voltage BYV26A BYV26B BYV26C BYV26D BYV26E BYV26F BYV26G |
- - - - - - - |
200 400 600 800 1000 1200 1400 |
V V V V V V V | |
IF(AV) |
average forward current BYV26A to E BYV26F and G |
Ttp = 85; lead length = 10 mm see Fig.2and 3; averaged over any 20 ms period; see also Fig10 and 11 |
- - |
1.00 1.05 |
A A |
IF(AV) |
average forward current BYV26A to E BYV26F and G |
Tamb = 60; PCB mounting (seeFig.19); see Figs 4 and 5; averaged over any 20 ms period;see also Figs 10 and 11 |
- - |
0.65 0.68 |
A A |
IFRM |
repetitive peak forward current BYV26A to E BYV26F and G |
Ttp = 85; see Figs 6 and 7 |
- - |
10.0 9.6 |
A A |