BGY118B, BGY122B, BGY132 Selling Leads, Datasheet
MFG:PHI Package Cooled:4/ D/C:99
BGY118B, BGY122B, BGY132 Datasheet download
Part Number: BGY118B
MFG: PHI
Package Cooled: 4/
D/C: 99
MFG:PHI Package Cooled:4/ D/C:99
BGY118B, BGY122B, BGY132 Datasheet download
MFG: PHI
Package Cooled: 4/
D/C: 99
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: BGY1085
File Size: 57214 KB
Manufacturer: PHILIPS [Philips Semiconductors]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: BGY122B
File Size: 99708 KB
Manufacturer: PHILIPS [Philips Semiconductors]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: BGY1085
File Size: 57214 KB
Manufacturer: PHILIPS [Philips Semiconductors]
Download : Click here to Download
SYMBOL | PARAMETER | MIN. | MAX. | UNIT |
VS1 | DC supply voltage | 10 | V | |
VS2 | DC supply voltage | 3.5 | V | |
PD | input drive power | 5 | mW | |
PL | load power | 1.6 | W | |
Tstg | storage temperature | -40 | 100 | C |
Tmb | operating mounting-base temperature | -30 | 100 | C |
The BGY132 and BGY133 are two stage amolifier modules.Each module compries two NPN silicon planar transistor chips together with lumped-element matching components.
The BGY132 and BGY133 has 4 features.The first one is broadband VHF amplifiers.The second one is 18 W output power.The third one is operate directly from 12 V vehicle electrical systems.The fourth one is output power control over a 10 dB range by drive power.
This production contains beryllium oxide.The product is entirely safe provided that the BeO slab is not damaged.All persons who handle,use or dispose of this product should be aware of its nature and of the necessary safety precautions.After use ,dispose of as chemical or special waste according to the regulations applying at the location of the user.It must never be thrown out with the general or dometic waste.
These products are not designed for use in life support appliances,devices,or systems where malfunction of these products can reasonably be expected to result in personal injury.Philips custormer using or selling these products for use in such applications do so their own risk and agree to fully indemnify philips for any damages resulting from such improper use or sale.