Features: · Meets or Exceeds the Requirements of ANSI Standards EIA/TIA-422-B and EIA/TIA-423-B and ITU RecommendationsV.10 and V.11· Operates From Single 5-V Power Supply· Wide Common-Mode Voltage Range· High Input Impedance· TTL-Compatible Outputs· High-Speed Schottky Circuitry· 8-Pin Dual-in-Li...
uA9637AC: Features: · Meets or Exceeds the Requirements of ANSI Standards EIA/TIA-422-B and EIA/TIA-423-B and ITU RecommendationsV.10 and V.11· Operates From Single 5-V Power Supply· Wide Common-Mode Voltage ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
· Meets or Exceeds the Requirements of ANSI Standards EIA/TIA-422-B and EIA/TIA-423-B and ITU Recommendations
V.10 and V.11
· Operates From Single 5-V Power Supply
· Wide Common-Mode Voltage Range
· High Input Impedance
· TTL-Compatible Outputs
· High-Speed Schottky Circuitry
· 8-Pin Dual-in-Line and Small-Outline Packages
· Designed to Be Interchangeable With National DS9637A
Supply voltage range, VCC (see Note 1) .........................................0.5 V to 7 V
Input voltage, VI ....................................................................................... ±15 V
Differential input voltage, VID (see Note 2)................................................ ±15 V
Output voltage range, VO (see Note 1) ....................................... 0.5 V to 5.5 V
Low-level output current, IOL .................................................................... 50 mA
Continuous total dissipation..................................... See Dissipation Rating Table
Operating free-air temperature range, TA ...................................... 0°C to 70°C
Storage temperature range, Tstg...............................................65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds............... 260°C
† Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential input voltage, are with respect to the network ground terminal.
2. Differential input voltage is measured at the noninverting input with respect to the corresponding inverting input.
The uA9637AC is a dual differential line receiver designed to meet ANSI Standards EIA/TIA-422-B and EIA/TIA-423-B and ITU Recommendations V.10 and V.11. The line receiver utilizes Schottky circuitry and has TTL-compatible outputs. The inputs are compatible with either a single-ended or a differential-line system. uA9637AC operates from a single 5-V power supply and is supplied in an 8-pin dual-in-line package or small-outline package.
The uA9637AC is characterized for operation from 0°C to 70°C.