Features: `Includes AT command set interpreter in on-chip ROM- no external memory required`Supports Tone dial or Pulse dial`Call progress monitoring controls`Handshake controls`Guard Tone controls`Line quality monitoring and Auto-Retrain`Auto-Dial and Auto-Answer`Glueless interface to Z02201 modem...
Z02205: Features: `Includes AT command set interpreter in on-chip ROM- no external memory required`Supports Tone dial or Pulse dial`Call progress monitoring controls`Handshake controls`Guard Tone controls`L...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter | Min | Max | Units | Notes |
Ambient Temperature under Bias | 0 | +70 | C | |
Storage Temperature | -65 | +150 | C | |
Voltage on any Pin with Respect to VSS | -0.6 | +7 | V | 1 |
Voltage on VDD Pin with Respect to VSS | -0.3 | +7 | V | |
Voltage on XTAL1 and RESET Pins with Respect to VSS | -0.6 | VDD+1 | V | 2 |
Total Power Dissipation | 1.21 | W | ||
Maximum Allowable Current out of VSS | 220 | mA | ||
Maximum Allowable Current into VDD | 180 | mA | ||
Maximum Allowable Current into an Input Pin | -600 | +600 | A | 3 |
Maximum Allowable Current into an Open-Drain Pin | -600 | +600 | A | 4 |
Maximum Allowable Output Current Sinked by Any I/O Pin | 25 | mA | ||
Maximum Allowable Output Current Sourced by Any I/O Pin | 25 | mA |
The Z02205 V.22bis Modem Controller serves as the modem controller in embedded V.22bis modem applications. A complete modem can be made by adding ZiLOG data pump (Z02201), phone line interface, and the required DTE interface. The Z02205 has been designed for low-cost use and includes a glueless interface to the ZiLOG data pumps.
The Z02205 is ideal for applications where small size and low power consumption are requirements. The Z02205 operates over dial-up telephone connections, provides auto-dial and ring detect, and operates in either SYNC or ASYNC modes.
The Z02205 includes AT command and modem control firmware in on-chip ROM. It also includes enhanced wakeup
circuitry, programmable Watch-Dog Timers (WDT), and low-noise/EMI options.
AT commands stored on-chip in ROM provide control over the following modem controller functions:
`Call progress monitoring
`Handshake negotiation
`Dial controls-pulse or tone
` S-registers
` Auto-answer and auto-dial
` Guard tones
` On-hook and off-hook
` Auto-retrain
Standard Z02205 sample devices and demonstration boards contain controller code tailored for operation on the North American phone network. For production usage, customers must modify the controller code to meet the requirements of their particular country and application.