SHM-4860

Features: • 200ns Maximum acquisition time• ±0.01% Accuracy• 100ns Maximum sample-hold settling time• 74dB Feedthrough attenuation• ±50ps Aperture uncertainty• Industry standardSpecifications ±15V Supply Voltages, Pins 24, 22 ±18V +5V Supply Voltage, ...

product image

SHM-4860 Picture
SeekIC No. : 004489779 Detail

SHM-4860: Features: • 200ns Maximum acquisition time• ±0.01% Accuracy• 100ns Maximum sample-hold settling time• 74dB Feedthrough attenuation• ±50ps Aperture uncertainty• In...

floor Price/Ceiling Price

Part Number:
SHM-4860
Supply Ability:
5000

Price Break

  • Qty
  • 1~5000
  • Unit Price
  • Negotiable
  • Processing time
  • 15 Days
Total Cost: $ 0.00

SeekIC Buyer Protection PLUS - newly updated for 2013!

  • Escrow Protection.
  • Guaranteed refunds.
  • Secure payments.
  • Learn more >>

Month Sales

268 Transactions

Rating

evaluate  (4.8 stars)

Upload time: 2024/11/21

Payment Methods

All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

Notice: When you place an order, your payment is made to SeekIC and not to your seller. SeekIC only pays the seller after confirming you have received your order. We will also never share your payment details with your seller.
Product Details

Description



Features:

• 200ns Maximum acquisition time
• ±0.01% Accuracy
• 100ns Maximum sample-hold settling time
• 74dB Feedthrough attenuation
• ±50ps Aperture uncertainty
• Industry standard



Specifications

±15V Supply Voltages, Pins 24, 22
±18V
+5V Supply Voltage, Pin 9
0.5V to +7V
Analog Input, Pin 13
±18V
Digital Inputs, Pins 11, 12
0.5V to +7V
Output Current
±65mA


Footnotes:
Input signal should not exceed the supply voltage.
The SHM-4860's output is current limited at approximately ±65mA. The device can withstand a sustained short to ground. However, shorts from the output to either supply will cause permanent damage. For normal operation, the load current should not exceed ±40mA.




Description

DATEL's SHM-4860 is a high-speed, highly accurate samplehold amplifier designed for precision, high-speed analog signal processing applications. Manufactured using modern, highquality hybrid technology, the SHM-4860 features excellent dynamic specifications including a maximum acquisition time of only 200ns for a 10V step to ±0.01%. Sample-to-hold settling time, to ±0.01% accuracy, is 100ns maximum with an aperture uncertainty of ±50ps.

The SHM-4860 is a complete sample-hold circuit, containing a precision MOS hold capacitor and a MOSFET SHM-4860 switching configuration which results in faster switching and better feedthrough attenuation. Additionally, a FET-input amplifier design allows faster acquisition and settling times while maintaining a considerably lower droop rate.