Features: • Ring SLIC eliminates ring relay and conventional ring-generator• Supports sine wave and trapezoidal ringing• -85 V battery feed for high voltage ring signal• On chip automatic battery switch• Programmable battery feed characteristics• Battery supply ...
PBL38711: Features: • Ring SLIC eliminates ring relay and conventional ring-generator• Supports sine wave and trapezoidal ringing• -85 V battery feed for high voltage ring signal• On c...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter | Symbol |
Min |
Max |
Unit |
Temperature, Humidity | ||||
Storage temperature range Operating junction temperature range |
TStg TJ |
-55 -40 |
+150 +140 |
°C °C |
Power supply, -40°C TAmb 85°C | ||||
VCC with respect to AGND VEE with respect to AGND VBat with respect to BGND VBat2 with respect to BGND |
VCC VEE VBat VBat2 |
-0.5 -6.5 -85 VBat |
6.5 0.5 VEE + 0.5 VEE + 0.5 |
V V V V |
Power dissipation | ||||
Continuous power dissipation at TAmb 85 °C Peak power dissipation at TAmb = 85 °C, t < 100 ms, tRep > 1 sec. |
PD PDP |
1.5 4 |
W W | |
Ground | ||||
Voltage between AGND and BGND | VG | -0.3 | 0.3 | V |
Digital inputs, outputs (C1, C2, E1, HB, DET) Input voltage Output voltage (DET disabled) Output current (DET enabled) |
VID VOD IOD |
0 0 |
VCC VCC 5 |
V V mA |
Ring voltage, input (VR) | ||||
Input voltage | VVR | VEE | VCC | V |
TIPX and RINGX terminals, -40°C T 85°C, V = -80V, Active, Disconnect and Stand by states | ||||
TIPX or RINGX voltage, continuous (referenced to AGND), Note 1 TIPX or RINGX, pulse < 10 ms, tRep > 10 s, Note 1 TIPX or RINGX, pulse < 1 µs, tRep > 10 s, Note 1 TIP or RING, pulse < 250 ns, tRep > 10 s, Note 1 TIPX or RINGX maximum current supplied |
VTA, VRA VTA, VRA VTA, VRA VTA, VRA |
VBat VBat - 5 VBat - 25 VBat - 35 |
2 5 10 15 110 |
V V V V mA |
The PBL 387 10/1 ring SLIC (Subscriber Line Interface Circuit) is a bipolar integrated circuit in 90 V technology which replaces the conventional transformer based analog line interface and ringrelay in FITL, WLL, ISDN-TA and other telecommunications equipment with a modern, compact solid state design. Not only is required PCB area reduced, but less component weight and height result as well. The PBL 387 10/1 has been optimized for low cost and to require only a minimum of external components.
The PBL 387 10/1 constant-current feed system, programmable to max 40 mA of line current, can operate with battery supply voltages down to -21 V to reduce line card power dissipation. The SLIC incorporates loop current, ground key and ring trip detection functions.
Two-to four-wire and four- to two-wire voice frequency (vf) signal conversion ofPBL38711 is accomplished by the SLIC in conjunction of PBL38711 with either a conventional CODEC/filter or with a programmable CODEC/filter (e.g. SLAC, SiCoFi, Combo II). The programmable line terminating impedance could be complex or real to fit every market. The PBL 387 10/1 package is 28-pin PLCC.