Features: • Selectable overhead voltage principle All adaptive: The overhead voltage follows 0.6 VPeak < signals < 6.2 VPeak. Semi adaptive: The overhead voltage follows 3.1 VPeak < signals < 6.2 VPeak.• Metering 2.2 Vrms.• High and low battery with automatic switchi...
PBL38661/2: Features: • Selectable overhead voltage principle All adaptive: The overhead voltage follows 0.6 VPeak < signals < 6.2 VPeak. Semi adaptive: The overhead voltage follows 3.1 VPeak < ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter | Symbol | Min. | Max | Unit |
Temperature, Humidity | ||||
Storage temperature range | TStg | -55 | +150 | |
Operating temperature range | TAmb | -40 | +110 | |
Operating junction temperature range, Note 1 | TJ | -40 | +140 |
The PBL 386 61/2 Subscriber Line Interface Circuit (SLIC) is a 90 V bipolar integrated circuit for use in Central Office, MUX and other telecommunications equipment. The PBL 386 61/2 has been optimized for low total line interface cost and a high degree of flexibility in different applications.
The PBL 386 61/2 emulates a transformer equivalent dc-feed, programmable between 2x25 and 2x900 , with short loop current limiting adjustable to max 65 mA.
A second lower battery voltage may be connected to PBL38661/2 to reduce short loop power dissipation. The SLIC automatically switches between the two battery supply voltages without need for external components or external control.
The SLIC incorporates loop current and ring trip detection functions of PBL38661/2. The PBL 386 61/2 is compatible with loop start signalling.
Two- to four-wire and four- to two-wire voice frequency (vf) signal conversion of PBL38661/2 is accomplished by the SLIC in conjunction with either a conventional CODEC/filter or with a programmable CODEC/filter, e.g. SLAC, SiCoFi, Combo II. The programmable ine terminating impedance could be complex or real to fit every market.
Longitudinal line voltages of PBL38661/2 are suppressed by a feedback loop in the SLIC and the longitudinal balance specifications meet Bellcore TR909 requirements.
The PBL 386 61/2 package is 28-pin PLCC.