Features: • Dual Filtering Lines for 2−Channels or Differential Transmission• Separate Power and Analog Grounds for ESD Protection and Filtering Circuitry• VCC Input Pin on First Stage to Set Microphone DC Bias• IEC 61000−4−2 Grade ±15 kV Contact ESD Prote...
NMF3010: Features: • Dual Filtering Lines for 2−Channels or Differential Transmission• Separate Power and Analog Grounds for ESD Protection and Filtering Circuitry• VCC Input Pin on F...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Rating | Symbol |
Value |
Units |
Operating Ambient Temperature Range | TA |
−40 to 85 |
°C |
Moisture Sensitivity | MSL |
Level 1 |
|
Storage Temperature Range | Tstg |
−55 to 150 |
°C |
Supply Voltage | VCC |
0 to 11 |
V |
The NMF3000 and the NMF3010 are a dual−stage, differential line ESD and filtering protection scheme for input signals into portable devices. The NMF3000 is the first stage and is located at or very near to the interface to the outside world. NMF3010 provides the high−level ESD protection as well as the initial filtering of incoming audio signals. The NMF3010 is the second stage and provides additional signal filtering. This second stage can be placed some distance away from the first stage to allow for effective filtering across extended distances.