Specifications Parameter Symbol Value Unit Peak Repetitive Forward and Reverse Blocking Voltage(1)(TJ = 40 to 110°C,1/2 Sine Wave, RGK = 1kW)MCR72-2MCR72-3MCR72-4MCR72-6MCR72-8MCR72-10 VDRMVRRM 50100200400600800 Volts On-State RMS Current (TC = 83°C) ITM 8...
MCR72-2: Specifications Parameter Symbol Value Unit Peak Repetitive Forward and Reverse Blocking Voltage(1)(TJ = 40 to 110°C,1/2 Sine Wave, RGK = 1kW)MCR72-2MCR72-3MCR72-4MCR72-6MCR72-8...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter |
Symbol |
Value |
Unit |
Peak Repetitive Forward and Reverse Blocking Voltage(1) (TJ = 40 to 110°C, 1/2 Sine Wave, RGK = 1kW) MCR72-2 MCR72-3 MCR72-4 MCR72-6 MCR72-8 MCR72-10 |
VDRM VRRM |
50 100 200 400 600 800 |
Volts |
On-State RMS Current (TC = 83°C) |
ITM |
8 |
Amps |
Peak Non-repetitive Surge Current (1/2 Cycle, 60 Hz, TJ = 40 to 110°C) |
IT(RMS) |
100 |
Amps |
Circuit Fusing (t = 8.3 ms) |
I2t |
40 |
A2s |
Peak Gate Voltage (t 10 s) |
IGM |
± 5 |
Volts |
Peak Gate Current (t 10 s) |
PGM |
1 |
Amp |
Peak Gate Power (t 10 s) |
PG(AV) |
5 |
Watt |
Average Gate Power |
PG(AV) |
0.75 |
Watts |
Operating Junction Temperature Range |
TJ |
40 to +110 |
°C |
1. VDRM and VRRM for all types can be applied on a continuous basis. Ratings apply for zero or negative gate voltage; (cont.) however, positive gate voltage shall not be applied concurrent with negative potential on the anode. Blocking voltages shall not be tested with a constant current source such that the voltage ratings of the devices are exceeded.