Features: `LOW CONSUMPTION IN STANDBY MODE (<100A AT ROM TEMP; < 150A AT 130°C)`TWO HALF BRIDGES FOR 3A LOAD (RDSON = 0.25 TYP; Tj = 25°C)`TWO HALF BRIDGES FOR 0.5A LOAD (RDSON = 2.5 TYP; Tj = 25°C)`HIGH SIDE DRIVER FOR 2.5A LOAD (RDSON = 0.45 TYP; Tj = 25°C)`DIRECT CONTROLLED BY C (MULTIPLE...
L9947: Features: `LOW CONSUMPTION IN STANDBY MODE (<100A AT ROM TEMP; < 150A AT 130°C)`TWO HALF BRIDGES FOR 3A LOAD (RDSON = 0.25 TYP; Tj = 25°C)`TWO HALF BRIDGES FOR 0.5A LOAD (RDSON = 2.5 TYP; Tj =...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
US $2.68 - 3.94 / Piece
Motor / Motion / Ignition Controllers & Drivers Integrated Stepper Bipolar Motor Driver
`LOW CONSUMPTION IN STANDBY MODE (<100A AT ROM TEMP; < 150A AT 130°C)
`TWO HALF BRIDGES FOR 3A LOAD (RDSON = 0.25 TYP; Tj = 25°C)
`TWO HALF BRIDGES FOR 0.5A LOAD (RDSON = 2.5 TYP; Tj = 25°C)
`HIGH SIDE DRIVER FOR 2.5A LOAD (RDSON = 0.45 TYP; Tj = 25°C)
`DIRECT CONTROLLED BY C (MULTIPLEX SYSTEM)
`OUTPUT HIGH/LOW LEVELDIAGNOSTIC
`OVERCURRENT SWITCH OFF AND DIAGNOSTIC
`OVERTEMPERATURE DIAGNOSTIC BEFORE SWITCH OFF
`OPEN LOAD DIAGNOSTIC
Symbol | Parameter | Value | Unit |
VS | DC Supply Voltage | 26 | V |
Single Pulse tmax < 400ms | 40 | V | |
IS | Negative Supply Current | -9 | A |
VCC | Stabilized Supply Voltage | -0.3 to 6V | V |
VCSN, VR/WN VMODE |
Digital Input Voltage | -0.3 to VCC+0.3 | V |
VD0 -D3 | Digital Input/ Output Voltage | -0.3 to VCC+0.3 | V |
IOUT1 -OUT5 | Output Current Power | internal limited | |
Tj | Operating Junction Temperature | -40 to 150 | °C |
Tj - SD | Thermal Shutdown Junction Temperature | min 150 | °C |
Tj - HYS | Thermal Junction Temperature Hysteresis | 20 | K |
The L9947 is a bus controlled power interface intended for automotive applications realized in multipower BCD60II technology. Up to three DC motors and one grounded resistive load can be driven with its four half-bridge and one high-side driver power outputs. The L9947 compatible bidirectional parallel bus allows several interfaces connected on the same bus (multiplex system). The full diagnostic information is available on the bus.