Features: • Bar graph chronograph and elapsed time displays• Lap memory (max 10 laps)• Lap/split time selectable• 3.0 V single power supply• Alarm/time signal function• 12/24-hour display selectableSpecifications No. Characteristics Symbol Rating Unit ...
JTMP0360-002S: Features: • Bar graph chronograph and elapsed time displays• Lap memory (max 10 laps)• Lap/split time selectable• 3.0 V single power supply• Alarm/time signal function&...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
DescriptionThe JTMP04020-XXXS is a kind of high-performance LL microcontroller developed for use i...
DescriptionThe JTMP04030-XXXS is a high performance 4 bit LL microcontroller desinged to be used i...
DescriptionThe JTMP0350-00115 is a low-power LSI for watches with chronograph functions.This LSI f...
No. | Characteristics | Symbol | Rating | Unit |
1 | Power supply voltage (1) | VSS − VDD1 | −0.2~+3.0 | V |
2 | Power supply voltage (2) | VSS − VDD2 | −0.2~+5.0 | V |
3 | Power supply voltage (3) | VSS − VDD3 | −0.2~+6.5 | V |
4 | VDD1 system input voltage | VIN1 | VSS − 0.2~VDD1 + 0.2 | V |
5 | VDD2 system input voltage | VIN2 | VSS − 0.2~VDD2 + 0.2 | V |
6 | VDD3 system input voltage | VIN3 | VSS − 0.2~VDD3 + 0.2 | V |
7 | VDD1 system output withstanding voltage | VOUT1 | VSS − 0.2~VDD1 + 0.2 | V |
8 | VDD2 system output withstanding voltage | VOUT2 | VSS − 0.2~VDD2 + 0.2 | V |
9 | VDD3 system output withstanding voltage | VOUT3 | VSS − 0.2~VDD3 + 0.2 | V |
10 | Operating temperature range | Topr | −10~+60 | °C |
11 | Storage temperature range | Tstg | −40~+125 | °C |
TIME mode JTMP0360-002S is used to display the current time and make time settings.
• Middle row columns #2 and #3 display the month, columns #4 and #5 display the day of the month with unnecessary zeros suppressed.
• Upper row columns #15 and #16 display the day of the week.
• Lower row column #8 displays AM/PM.
• Lower row columns #9 and #10 display the hour, columns #11 and #12 display minutes, and #13 and #14 display seconds.
• The ON/OFF states of the time signal and alarm are displayed in the upper right corner.
• When the alarm or time signal is set, the alarm or time signal sign in the top row flashes.
When the LAP or SPLIT functions are running in CHRONO mode, the LAP or SPLIT signs flash.
• Pressing multiple switches simultaneously invalidates the switches pressed.
• Pressing a second switch while still pressing the first invalidates both switches.
• S2 can be used to switch between a 12-and 24-hour clock. Such switching can only be performed in TIME mode.