Features: • Performs bidirectional power and energy measurement• Meets the IEC 521/1036 Specification requirements for Class 1 AC Watt hour meters• Protected against ESD• Total power consumption rating below 25 mW• Adaptable to different types of current sensors•...
ILA19002: Features: • Performs bidirectional power and energy measurement• Meets the IEC 521/1036 Specification requirements for Class 1 AC Watt hour meters• Protected against ESD• Tot...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter | Symbol | Min | Max | Unit |
Supply Voltage | VDD -VSS | -0.3 | 6.0 | V |
Current on any Pin | IPIN | -150 | +150 | mA |
Storage Temperature | Tstg | -40 | +125 | |
Operating Temperature | TO | -40 | +85 |
The ILA19002 Single Phase Bidirectional Power/Energy metering integrated circuit generates a pulse rate output, the frequency of which is proportional to the power consumption. The ILA19002 performs the calculations of active power.
The method of calculation takes the power factor into account. Energy consumption is determined by the power measurement being integrated over time. This universal single phase bidirectional power/energy metering integrated circuit is ideally suited for energy calculation in applications such as residential municipal metering and factory energy metering and control. The ILA19002 Single Phase Bidirectional Power/Energy metering integrated circuit is a CMOS mixed signal Analog/Digital integrated circuit, which performs power/energy calculations over a range of 1000:1, to an overall accuracy of better than Class 1.
The integrated circuit includes all the required functions for 1-phase power and energy measurement such as two oversampling A/D converters for the voltage and current sense inputs, power calculation and energy integration. Internal offsets are eliminated through the use of cancellation procedures. The ILA19002 Single Phase Bidirectional Power/Energy metering integrated circuit generates pulses, the frequency of which is proportional to the power consumption.
The pulse rate of the ILA19002 follows the instantaneous power consumption measured. Direction information is also provided. A voltage zero crossover signal, relevant to the positive going half cycle, is available on pin FMO. This signal can be used to synchronise circuit breaker switching. IC is available in both 14 and 20 pin dual-in-plastic (DIP-14/DIP-20), as well as 20 pin small outline (SOIC-20) package types.