Features: `No potentiomenter required`Direct interface to SCR`Supply voltage derived from AC line 26V shunt`Adjustable sensitivity`Grounded neutral fault detection`Meets U.L. 943 standards`450 A quiescent current`Ideal for 120 V or 220 V systemsPinoutSpecifications Symbol Parameter V...
IL4145A: Features: `No potentiomenter required`Direct interface to SCR`Supply voltage derived from AC line 26V shunt`Adjustable sensitivity`Grounded neutral fault detection`Meets U.L. 943 standards`450 A qu...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol |
Parameter |
Value |
Units |
ICC |
Supply Current |
18 |
mA |
PD |
Internal Power Dissipation |
500 |
mW |
Tstg |
Storage Temperature Range |
-65 to +150 |
°C |
Topr |
Operating Temperature Range |
-35 to +85 |
°C |
TJ |
Junction Temperature |
125 |
°C |
TL |
Lead Temperature |
125 |
°C |
PD |
TA< 50°C |
450 |
mW |
For TA> 50°C Derate at |
6 |
mW/°C |
The IL4145AN is a low power controller for AC outlet ground fault interrupters. These devices detect hazardous grounding conditions, such as equipment (connected to opposite phases of the AC line) in contact with a pool of water and open circuits the line before a harmful or lethal shock occurs.
Contained internally are a 26V zener shunt regulator, an op amp, and an SCR driver. With the addition of two sense transformers, a bridge rectifier, an SCR, a relay, and a few additional components, the IL4145AN will detect and protect against both hot wire to ground and neutral wire to ground faults. The simple layout and conventional design ensure ease of application and long-term reliability.