Features: `SPACE SAVING : MONOLITHIC FIRE LIGHTER FUNCTION INTEGRATION`DEDICATED THYRISTOR STRUCTURE FOR CAPACITANCE DISCHARGE IGNITION OPERATION`HIGH PULSE CURRENT CAPABILITY 240A@tp= 10s`AVAILABLEIN THROUGHHOLE PACKAGESpecifications Symbol Parameter Value Unit ITRM Repetiti...
FLC10-200D: Features: `SPACE SAVING : MONOLITHIC FIRE LIGHTER FUNCTION INTEGRATION`DEDICATED THYRISTOR STRUCTURE FOR CAPACITANCE DISCHARGE IGNITION OPERATION`HIGH PULSE CURRENT CAPABILITY 240A@tp= 10s`AVAILABLE...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
`SPACE SAVING : MONOLITHIC FIRE LIGHTER FUNCTION INTEGRATION
`DEDICATED THYRISTOR STRUCTURE FOR CAPACITANCE DISCHARGE IGNITION OPERATION
`HIGH PULSE CURRENT CAPABILITY 240A@tp= 10s
`AVAILABLEIN THROUGHHOLE PACKAGE
Symbol |
Parameter |
Value |
Unit | |
ITRM |
Repetitive surge peak on state current for thyristor | tp = 10s ( note 1) |
240 |
A |
IFRM |
Repetitive surge peak on state current for diode | |||
di/dt |
Critical rate of rise time on state current |
200 |
A/s | |
Tstg |
Storage junction temperature range |
- 40 to + 150 |
°C | |
Tj |
Maximum junction temperature |
+ 125 | ||
Toper |
Operating temperature range |
-30 + 120 |
°C | |
TL |
Maximum lead temperature for soldering during 10s |
260 |
°C |
- The FLC10-200D is a high performance planar diffused technology adapted to high temperatureand rugged environmental conditions.
- FLC10-200D has been developed especially for capacitance discharge operation. The main applications are gas lighter or ignitor such as:cookers / gas boilers / gas hobs...