Features:
Military temperature range Input voltage range of +7.0V (differential or common mode) +0.2V sensitivity over theinput voltage range. High input impedance Operation from single +5.0V supply Input pull-down resistor prevents output oscillation on unused channels TRI-STATE outputs, with choice of complementary enables, for receiving directly on adata bus
Specifications
Storage Temperature Range -65 C < Ta < +150 C Operating Temperature Range -55 C < Ta < +125 C Lead TemperatureSoldering, 60 seconds 300 C Supply Voltage 7.0V Common Mode Voltage Range +25V Differential Input Voltage +25V Enable Voltage 7.0V Output Sink Current 50mA Maximum Power Dissipation (Pd) @ +25C(Note 2) 500mW Thermal Resistance (JA) J package 100 C/W W package 142 C/W E package 87 C/W