ATM ICs
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Maximum Operating Temperature : | + 85 C | Minimum Operating Temperature : | - 40 C |
Voltage Range on Any Pin with Respect to VSS (except VDD).... -0.3V to +5.5V
Supply Voltage (VDD) Range with Respect to VSS ....................-0.3V to +3.63V
Operating Temperature Range ..................................................-40 to +85
Storage Temperature Range ...................................................-55 to +125
Soldering Temperature ..........................................See IPC/JEDEC J-STD-020A
Stresses beyond those listed under 'Absolute Maximum Ratings' may cause permanent damage to the device.These are stress ratings only,and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device.
On the transmit side, the DS26102 receives ATM cells from an ATM device through a UTOPIA II interface,provides cell buffering (up to 4 cells), HEC generation and insertion, cell scrambling, and converts the data to a serial stream appropriate for interfacing to a T1/E1 framer or transceiver. On the receive side, the DS26102 receives a TDM stream from a T1/E1 framer or transceiver; searches for the cell alignment; verifies the HEC; provides cell filtering, descrambling, and cell buffering; and passes the cells to an ATM device through the UTOPIA II interface. Other low-level traffic management functions are selectable for the transmit and receive paths. The DS26102 can also be used in
fractional T1/E1 applications.
The DS26102 maps ATM cells to T1/E1 TDM frames as per the ATM Forum Specifications af-phy-0016.000 and af-phy-0064.000. In the receive direction, the cell delineation mechanism used for finding ATM cell boundary within T1/E1 frame is performed as per ITU I.432. The DS26102 provides a mapping solution for up to 16 T1/E1 TDM ports. The terms physical layer (PHY) and line side are used synonymously in this document and refer to the device interfacing with the line side of the DS26102. The terms ATM layer and system side are used synonymously and refer to the DS26102,s UTOPIA II interface.