Features: · Logic Level Input· Input Protection (ESD)· Thermal shutdown with auto restart· Overload protection· Short circuit protection· Overvoltage protection· Current limitation· Analog driving possibleApplication` All kinds of resistive, inductive and capacitive loads in switching or linear ap...
BSP 77: Features: · Logic Level Input· Input Protection (ESD)· Thermal shutdown with auto restart· Overload protection· Short circuit protection· Overvoltage protection· Current limitation· Analog driving p...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter |
Symbol |
Values |
Unit |
Continuous drain source voltage (overvoltage protection see page 4) |
VDS |
42 |
V |
Supply voltage for full short circuit protection |
Vbb(SC) |
42 |
V |
Continuous input voltage1) |
VIN |
-0.22) ... +10 |
V |
Continuous input current2) -0.2V VIN 10V VIN < -0.2V or VIN > 10V |
VIN |
self limited | IIN | 2 |
V |
Operating temperature |
VIN |
-40 ...+150 |
V |
Storage temperature |
Tj Tstg |
-55 ... +150 |
°C |
Power dissipation 5) TC = 85 °C |
Ptot |
3.8 |
W |
Unclamped single pulse inductive energy 2) |
EAS |
250 |
mJ |
Load dump protection VLoadDump2)3) = VA + VS VIN = 0 and 10 V, td = 400 ms, RI = 2 , RL = 6 , VA = 13.5 V |
EAS |
50 |
mJ |
Electrostatic discharge voltage2) (Human Body Model) according to Jedec norm EIA/JESD22-A114-B, Section 4 |
VESD |
2 |
KV |
Jedec humidity category,J-STD-20-B |
MSL 1 |
||
IEC climatic category, DIN IEC 68-1 |
40/150/56 |