Features: • Provides Two Regulated Voltages- One Synchronous-Rectified Buck PWM Controller- One Linear Controller• Low Reference Voltage for Further Applications- Both Controllers : 0.8V ± 2% Over Temperature• Both Controllers Drive N-Channel MOSFETs- PWM Controller Drives Dual N...
APW7058: Features: • Provides Two Regulated Voltages- One Synchronous-Rectified Buck PWM Controller- One Linear Controller• Low Reference Voltage for Further Applications- Both Controllers : 0.8V...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol | Parameter | Rating | Unit |
5VCC | 5VCC Supply Voltage (5VCC to GND) | -0.3 ~ 7 | V |
12VCC | 12VCC Supply Voltage (12VCC to GND) | -0.3 ~ 15 | V |
UAGTE, DRIVE2 to GND | -0.3 ~ 12VCC | V | |
LGATE, FB, FB2 to GND | -0.3 ~ 5VCC | V | |
Maximum Junction Temperature | 150 | °C | |
TSTG | Storage Temperature | -65 ~ 150 | °C |
TSDR | Maximum Soldering Temperature, 10 Seconds | 300 | °C |
VESD | Minimum ESD Rating (Human body model) | ±2 | kV |
The APW7058 integrates one synchronous-rectified Buck PWM controller and one linear controller to provide two regulated voltages for graphics cards and other embedded processor applications. The PWM controller which drives dual N-channel MOSFETs uses fixed 600kHz frequency, voltage-mode PWM control and integrates power-on-reset(POR), built-in soft-start, output under-voltage monitoring and shutdown functions into a single chip. The linear controller which drives a N-channel MOSFET bypass transistor allows users to optimize the transient response by external components. The POR circuit with hysteresis monitors both 5VCC and 12VCC supply voltages to start up/shutdown the IC at power-on/off. An internal 0.8V temperature-compensated reference is designed to meet the low output voltage requirement for further applications. The built-in soft-start function sets the soft-start interval to prevent the output voltages from overshoot as well as limiting the input currents. The under-voltage protections monitor the voltages at FB and FB2 for short-circuit protection. The under-voltage protections cycle the soft-start function until 3 times of UVP events are happened. Pulling and holding the FB2 pin above 1.28V to disable the both controllers.