TPA6112, TPA6112A2, TPA6112A2DG Selling Leads, Datasheet
MFG:TI Package Cooled:MSOP-10 D/C:05+
TPA6112, TPA6112A2, TPA6112A2DG Datasheet download
Part Number: TPA6112
MFG: TI
Package Cooled: MSOP-10
D/C: 05+
MFG:TI Package Cooled:MSOP-10 D/C:05+
TPA6112, TPA6112A2, TPA6112A2DG Datasheet download
MFG: TI
Package Cooled: MSOP-10
D/C: 05+
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: TPA6112A2
File Size: 424170 KB
Manufacturer: TI [Texas Instruments]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: TPA6112A2
File Size: 424170 KB
Manufacturer: TI [Texas Instruments]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: TPA6112A2DGQ
File Size: 424170 KB
Manufacturer: TI [Texas Instruments]
Download : Click here to Download
The TPA6112A2 is a stereo audio power amplifier with differential inputs packaged in a 10-pin PowerPAD MSOP package capable of delivering 150 mW of continuous RMS power per channel into 16- loads. Amplifier gain is externally configured by means of two resistors per input channel and does not require external compensation for settings of 1 to 10.
UNITS | ||
VDD |
Supply voltage |
6 V |
VI |
Input voltage |
-0.3 V to VDD + 0.3 V |
Continuous total power dissipation |
internally limited | |
TJ |
Operating junction temperature range |
-40°C to 150°C |
Tstg |
Storage temperature range |
-65°C to 150°C |
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds |
260°C |
(1) Stresses beyond thoselisted under absolute maximum ratings may cause permanent damage to the device.These are stress ratings only, and functional operation of the device at theseor any other conditions beyond those indicated under recommended operatingconditions is not implied. Exposure to absolute-maximum-rated conditions forextended periods may affect device reliability.