TDA1519B/N2, TDA1519C, TDA1519C/N3 Selling Leads, Datasheet
MFG:NXP Package Cooled:SIP D/C:10
TDA1519B/N2, TDA1519C, TDA1519C/N3 Datasheet download

Part Number: TDA1519B/N2
MFG: NXP
Package Cooled: SIP
D/C: 10
MFG:NXP Package Cooled:SIP D/C:10
TDA1519B/N2, TDA1519C, TDA1519C/N3 Datasheet download

MFG: NXP
Package Cooled: SIP
D/C: 10
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: TDA 4601
File Size: 1417404 KB
Manufacturer:
Download : Click here to Download
PDF/DataSheet Download
Datasheet: TDA1519C
File Size: 116357 KB
Manufacturer: PHILIPS [Philips Semiconductors]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: TDA 4601
File Size: 1417404 KB
Manufacturer:
Download : Click here to Download
The TDA1519C is an integrated class-B dual output amplifier in a 9-lead plastic single in-line (SIL) power or 20-lead heatsink small outline package.
For the TDA1519CTH (SOT418-2) the heatsink is positioned on top of the package, thereby allowing an external heatsink to be mounted on top. The heatsink of the TDA1519CTD (SOT397-1) is facing the PCB thereby allowing the heatsink to be soldered on the copper area of the PCB.
| SYMBOL | PARAMETER | CONDITIONS | MIN. | MAX. | UNIT |
| VP | supply voltage | operating | - | 17.5 | V |
| non-operating | - | 30 | V | ||
| load dump protected; during 50 ms; tr 2.5 ms |
- | 45 | V | ||
| VSC | AC and DC short-circuit-safe voltage | - | 17.5 | V | |
| Vrp | reverse polarity voltage | - | 6 | V | |
| energy handling capability at outputs | VP = 0 V | - | 200 | mJ | |
| IOSM | non-repetitive peak output current | - | 6 | A | |
| IORM | repetitive peak output current | - | 4 | A | |
| Ptot | total power dissipation | see Fig.5 | - | 25 | W |
| Tj | junction temperature | - | 150 | °C | |
| Tstg | storage temperature | -55 | -55 | +150 | °C |
These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.