Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
These octal bus transceivers are designed for asynchronous two-way communication between data buses. The control-function implementation minimizes external timing requirements.
The 'HCT245 devices allow data transmission from the A bus to the B bus or from the B bus to the A bus, depending upon the logic level at the direction-control (DIR) input. The output-enable (OE) input can be used to disable the device so that the buses are effectively isolated.
† Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only,and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance is calculated in accordance with JESD 51-7.
SN54HCT245 Features
Operating Voltage Range of 4.5 V to 5.5 V High-Current 3-State Outputs Drive Bus Lines Directly or Up To 15 LSTTL Loads Low Power Consumption, 80-A Max ICC Typical tpd = 14 ns ±6-mA Output Drive at 5 V Low Input Current of 1 A Max Inputs Are TTL-Voltage Compatible