NL6448BC2008, NL6448BC20-08, NL6448BC20-08E Selling Leads, Datasheet
MFG:MEC Package Cooled:6.5 D/C:08+
NL6448BC2008, NL6448BC20-08, NL6448BC20-08E Datasheet download
Part Number: NL6448BC2008
MFG: MEC
Package Cooled: 6.5
D/C: 08+
MFG:MEC Package Cooled:6.5 D/C:08+
NL6448BC2008, NL6448BC20-08, NL6448BC20-08E Datasheet download
MFG: MEC
Package Cooled: 6.5
D/C: 08+
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: NL604
File Size: 565305 KB
Manufacturer:
Download : Click here to Download
PDF/DataSheet Download
Datasheet: NL6448BC20-08
File Size: 213984 KB
Manufacturer: NEC [NEC]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: NL604
File Size: 565305 KB
Manufacturer:
Download : Click here to Download
NL6448BC20-08 is a TFT (thin film transistor) active matrix color liquid crystal display (LCD) comprising amorphous silicon TFT attached to each signal electrode, a driving circuit and a backlight. NL6448BC20-08 has a built-in backlight. Backlight includes long-life lamps and the lamps are replaceable.
The 17 cm diagonal display area contains 640×480 pixels and can display 262144 colors simultaneously. NL6448BC20-08 is suitable for industrial application use, because the luminance is high, and the viewing direction is selectable with display scan select.
Parameters |
Symbol |
Rating |
Unit |
Remarks |
Supply voltage |
VCC |
0.3 to +6.0 |
V |
Ta = 25°C |
VDD |
0.3 to + 14 |
V | ||
Input voltage |
VI |
0.3 to VCC + 0.3 |
V |
VDD=12V,Ta= 25°C |
Lamp voltage |
VL |
0.3 to +5.5 |
V |
VDDB=12V,Ta = 25°C |
Storage temp. |
TST |
20 to + 60 |
°C |
- |
Operating temp. |
TOP |
0 to 50 |
°C |
Module surface |
RH
|
95% relative humidity
|
Ta 40°C | ||
85% relative humidity
|
40 < Ta 50°C | |||
Absolute humidity shall not exceed
Ta= 55°C, 70% relative humidity level. |
Ta > 50°C |