MAX1618MUB-TG096, MAX1619, MAX1619MEE. Selling Leads, Datasheet
MFG:MAXIM Package Cooled:MSOP10 D/C:0226+
MAX1618MUB-TG096, MAX1619, MAX1619MEE. Datasheet download
Part Number: MAX1618MUB-TG096
MFG: MAXIM
Package Cooled: MSOP10
D/C: 0226+
MFG:MAXIM Package Cooled:MSOP10 D/C:0226+
MAX1618MUB-TG096, MAX1619, MAX1619MEE. Datasheet download
MFG: MAXIM
Package Cooled: MSOP10
D/C: 0226+
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: MAX002
File Size: 42133 KB
Manufacturer: FILTRONIC [Filtronic Compound Semiconductors]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: MAX1619
File Size: 246443 KB
Manufacturer: MAXIM [Maxim Integrated Products]
Download : Click here to Download
PDF/DataSheet Download
Datasheet: MAX002
File Size: 42133 KB
Manufacturer: FILTRONIC [Filtronic Compound Semiconductors]
Download : Click here to Download
VCC to GND.......................................................-0.3V to +6V
DXP, ADD_ to GND ..............................-0.3V to (VCC + 0.3V)
DXN to GND ..................................................-0.3V to +0.8V
SMBCLK, SMBDATA, ALERT, OVERT
STBY to GND.....................................................-0.3V to +6V
SMBDATA,ALERT, OVERT Current..................-1mA to +50mA
DXN Current ...............................................................±1mA
ESD Protection (all pins, Human Body Model) ............2000V
Continuous Power Dissipation (TA = +70°C)
QSOP (derate 8.30mW/°C above +70°C)...............667mW
Operating Temperature Range ................-55°C to +125°C
Junction Temperature...............................................+150°C
Storage Temperature Range ....................-65°C to +150°C
Lead Temperature (soldering, 10sec) ......................+300°C
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.