CY23FP08ZC, CY23FP09ZC, CY23FP12 Selling Leads, Datasheet
MFG:CYP Package Cooled:TSSOP D/C:02+
CY23FP08ZC, CY23FP09ZC, CY23FP12 Datasheet download
Part Number: CY23FP08ZC
MFG: CYP
Package Cooled: TSSOP
D/C: 02+
MFG:CYP Package Cooled:TSSOP D/C:02+
CY23FP08ZC, CY23FP09ZC, CY23FP12 Datasheet download
MFG: CYP
Package Cooled: TSSOP
D/C: 02+
Want to post a buying lead? If you are not a member yet, please select the specific/related part number first and then fill the quantity and your contact details in the "Request for Quotation Form" on the left, and then click "Send RFQ".Your buying lead can then be posted, and the reliable suppliers will quote via our online message system or other channels soon.
TOP
PDF/DataSheet Download
Datasheet: CY2030
File Size: 89675 KB
Manufacturer: Cypress
Download : Click here to Download
PDF/DataSheet Download
Datasheet: CY2030
File Size: 89675 KB
Manufacturer: Cypress
Download : Click here to Download
PDF/DataSheet Download
Datasheet: CY23FP12
File Size: 206797 KB
Manufacturer: CYPRESS [Cypress Semiconductor]
Download : Click here to Download
Parameter | Description | Condition | Min. | Max. | Unit |
VDD | Supply Voltage | Non-functional | 0.5 | 7 | VDC |
VIN | Input Voltage REF | Relative to VCC | 0.5 | 7 | VDC |
VIN | Input Voltage Except REF | Relative to VCC | 0.5 | VDD + 0.5 | VDC |
LUI | Latch-up Immunity | Functional | 300 | mA | |
TS | Temperature, Storage | Non-functional | 65 | +125 | °C |
TA | Temperature, Operating Ambient | Commercial Temperature | 0 | +70 | °C |
TA | Temperature, Operating Ambient | Industrial Temperature | 40 | +85 | °C |
TJ | Junction Temperature | Industrial Temperature | 125 | °C | |
ØJc | Dissipation, Junction to Case | Functional | 34 | °C/W | |
ØJa | Dissipation, Junction to Ambient | Functional | 86 | °C/W | |
ESDh | ESD Protection (Human Body Model) | 2000 | V | ||
MSL | Moisture Sensitivity Level | MSL 1 | class | ||
GATES | Total Functional Gate Count | Assembled Die | 21375 | each | |
UL94 | Flammability Rating | @ 1/8 in. | V0 | class | |
FIT | Failure in Time | Manufacturing test | 10 | ppm | |
TPU | Power-up time for all VDDs to reach minimum specified voltage (power ramps must be monotonic) |
0.05 | 500 | ms |