Features: Accurate measurement of available capacity in Lithium primary batteries such as Lithium Sulphur Dioxide and Lithium Manganese DioxideProvides a low-cost battery monitor solution for pack integration - Complete circuit can fit less than 1 square inch of PCB space - Lowoperatingcurrent - L...
bq2052: Features: Accurate measurement of available capacity in Lithium primary batteries such as Lithium Sulphur Dioxide and Lithium Manganese DioxideProvides a low-cost battery monitor solution for pack i...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Symbol | Parameter | Minimum | Maximum | Unit | Notes |
VCC | Relative to VSS | -0.3 | 7.0 | V | |
All other pins | Relative to VSS | -0.3 | 7.0 | V | |
REF | Relative to VSS | -0.3 | 8.5 | V | Current limited by R1 (see Figure 1) |
VSR | Relative to VSS | -0.3 | Vcc+0.7 | V | Minimum 100K series resistor should be used to protect SR in case of a shorted battery. |
TOPR | Operating tempera ture |
-20 |
+70 |
°C |
Commercial Industrial |
The bq2052 Lithium Primary Gas Gauge IC is intended for battery-pack or in-system installation to maintain an accurate record of available battery capacity. The IC monitors a voltage drop across a sense resistor connected in series with the cells to determine discharge activity of the battery. The bq2052 applies compensations for battery temperature and discharge rate to the available charge counter to provide available capacity information across a wide range of operatingconditions.
Compensated available capacity may be directly indicated using an LED display. The LED display is programmable and can be configured as two, four,or five segments.These segments are used to depict available battery capacity. The bq2052 supports a single-wire serialcommunications link to an external micro-controller. The link allows the micro-controller to read and write the internal registers of the bq2052. The internal registers in-clude available battery capacity,voltage, temperature, current, and battery status. The controller may also overwrite some of the bq2052 gasgaugedataregisters.
The bq2052 can operate from the batteries in the pack. The REF output and an external FET provide a simple, inexpensive voltage regulator to supply power to the circuit fromthecells.