Features: • Low-Power Consumption• Wide Common-Mode and Differential Voltage Ranges• Low Input Bias and Offset Currents• Output Short-Circuit Protection• Low Total Harmonic Distortion . . . 0.003% Typ• High Input Impedance . . . JFET-Input Stage• Internal ...
TL081A: Features: • Low-Power Consumption• Wide Common-Mode and Differential Voltage Ranges• Low Input Bias and Offset Currents• Output Short-Circuit Protection• Low Total Harm...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
TL08_C TL08_AC TL08_BC |
TL08_I | TL08_M | UNIT | ||
Supply voltage, VCC+ (see Note 1) | 18 | 18 | 18 | V | |
ply voltage VCC (see Note 1) | 18 | 18 | 18 | V | |
Differential input voltage (see Note 2) | ± 30 | ± 30 | ± 30 | V | |
Input voltage (see Notes 1 and 3) | ±15 | ±15 | ±15 | V | |
Duration of output short circuit (see Note 4) | unlimited | unlimited | unlimited | ||
Continuous total dissipation | See Dissipation Rating Table | ||||
Operating free-air temperature range | 0 to 70 | 40 to 85 | 55 to 125 | ||
Storage temperature range | 65 to 150 | 65 to 150 | 65 to 150 | ||
Case temperature for 60 seconds | FK package | 260 | |||
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds |
Jor JG package | 300 | |||
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds |
D,N,P,or PW package | 260 | 260 |
The TL08_ JFET-input operational amplifier family is designed to offer a wider selection than any previously developed operational amplifier family. Each of these JFET-input operational amplifiers incorporates well-matched, high-voltage JFET and bipolar transistors in a monolithic integrated circuit. The devices feature high slew rates, low input bias and offset currents, and low offset voltage temperature coefficient. Offset adjustment and external compensation options are available within the TL08_ family.
Device types with a C suffix are characterized for operation from 0 to 70, those with an I suffix are characterized for operation from 40°C to 85, and those with an M suffix are characterized for operation over the full military temperature range of 55 to 125.