Features: Input voltage range: 2.2V~10V (VOUT type)Output voltage range: 1.5V~6.0V programmable in 0.1V steps (±2.5%)Oscillator frequency: 300kHz (±15%) Custom products for 180, 500kHzOutput Current: 1.0A + (VIN=5.0V, VOUT=3.0V)High Efficiency: 92% (typ.)Stand-by capability: ISTB=0.5A (max.)Soft-s...
XC6366: Features: Input voltage range: 2.2V~10V (VOUT type)Output voltage range: 1.5V~6.0V programmable in 0.1V steps (±2.5%)Oscillator frequency: 300kHz (±15%) Custom products for 180, 500kHzOutput Current...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
PARAMETER |
SYMBOL |
RATINGS |
UNITS |
VIN Pin Voltage |
VDD |
-0.3 ~ 12 |
V |
VOUT Pin Voltage |
VOUT |
-0.3 ~ VIN +0.3 |
V |
FB Pin Voltage |
VFB |
-0.3 ~ VIN +0.3 |
V |
CE Pin Voltage |
VCE |
-0.3 ~ VIN +0.3 |
V |
EXT/ Pin Voltage |
VEXT/ |
-0.3 ~ VIN +0.3 |
V |
EXT/ Pin Current |
IEXT/ |
±100 |
mA |
Continuous Total |
Pd |
150 |
mW |
Operating Ambient |
Topr |
-30 ~ +80 |
|
Storage Temperature |
Tstg |
-40 ~ +125 |
The XC6365/66 series are multi-functional step-down DC/DC converters with built-in high speed, low ON resistance drivers. An output current of more than 1A is possible using an externally connected transistor, coil, diode and capacitor.
Output voltage of XC6365/66 is programmable in 0.1V steps between 1.5V to 6.0V (VOUT) (±2.5% accuracy). Further, with 1.0V of standard voltage supply internal and using externally connected components, output voltage can be set up freely (FB).With a 300kHz switching frequency, the size of the external components can be reduced. Control switches from PWM to PFM during light loads with the XC6366 (PWM/PFM switchable) and the series is highly efficient from light loads to large output currents. In relation to soft-start time, both internally set-up 10msec types (A,B) and external resistor or capacitor regulated types (C,D) are available. During stand-by time (CE pin "Low" ), current consumption is reduced to less than 0.5A.With U.V.L.O internal, the external Tr. will be forcibly switched off if used below the stipulated voltage.