Features: · VERY HIGH ACCURACY: 4.5000 V OUTPUT ±0.4 mV· EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C· EXCELLENT STABILITY: 6ppm/1000 Hrs. Typ.· EXCELLENT LINE REGULATION: 6 ppm/V Typ.· WIDE SUPPLY RANGE: +13.5 V to +22.0 V· HERMETIC 20 TERMINAL CERAMIC LCC· MILITARY PROCESSING AVAILABLEApplica...
VRE204: Features: · VERY HIGH ACCURACY: 4.5000 V OUTPUT ±0.4 mV· EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C· EXCELLENT STABILITY: 6ppm/1000 Hrs. Typ.· EXCELLENT LINE REGULATION: 6 ppm/V Typ.· WIDE SUPP...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
MIN |
TPY |
MIN |
MIN |
TPY |
MIN |
MIN |
TPY |
MIN |
| |
Power Supply Operating Temperature Storage Temperature Short Circuit Protection |
±13.5 -25 -65 |
|
±22 85 150 |
* -55 * |
|
* 125 * |
* -55 * |
|
* 125 * |
V °C °C |
Continuous |
|
VRE204 Series Precision Voltage References provide ultrastable +4.500 V outputs with up to ±0.4 mV initial accuracy and temperature coefficient as low as 0.6 ppm/°C over the full military temperature range.
These references are specifically designed to be used with the Crystal Semiconductor line of successive-approximation type Analog-to-Digital Converters (ADCs). This line of ADCs sets new standards for temperature drift, which can only be as good as the external reference used. The Thaler VRE204 combined with a Crystal ADC will provide the lowest drift data conversion obtainable.
VRE204 series devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to +125°C, and two performance grades. All devices are packaged in 20 terminal LCC ceramic packages for maximum long-term stability. "M" versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make the VRE204 ideal for all precision applications which may require a 4.5V reference. High-accuracy test and measurement instrumentation, and transducer excitation are some other applications which can benefit from the high accuracy of the VRE204.