Features: · VERY HIGH ACCURACY: 4.5000 V OUTPUT ±0.4 mV· EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C· EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.· EXCELLENT LINE REGULATION: 6 ppm/V Typ.· WIDE SUPPLY RANGE: +13.5 to +22.0 V· HERMETIC 14-PIN CERAMIC DIP· MILITARY PROCESSING OPTIONSApplication· PR...
VRE104: Features: · VERY HIGH ACCURACY: 4.5000 V OUTPUT ±0.4 mV· EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C· EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.· EXCELLENT LINE REGULATION: 6 ppm/V Typ.· WIDE SUP...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
PinoutSpecificationsOutput (V)Initial Error (mV)Temperature Coefficient (ppm/°C)Noise (µ...
C |
CA |
M |
MA |
||||||||||
PARAMETERS |
MIN |
TYP |
MAX |
MIN |
TYP |
MAX |
MIN |
TYP |
MAX |
MIN |
TYP |
MAX |
UNITS |
Power Supply |
+13.5 |
+22 |
V | ||||||||||
Operating Temperature |
-25 |
85 |
-55 |
125 |
-55 |
125 |
°C | ||||||
Storage Temperature |
-65 |
150 |
°C | ||||||||||
Short Circuit Protection |
Continuous |
VRE104 Series Precision Voltage References provide ultrastable +4.500 V outputs with up to ±0.4 mV initial accuracy and temperature coefficient as low as 0.6 ppm/°C over the full military temperature range.
These references are specifically designed to be used with the Crystal Semiconductor line of successive-approximation type Analog to Digital Converters (ADCs). This line of ADCs sets new standards for temperature drift, which can only be as good as the external reference used. The Thaler VRE104 combined with a Crystal ADC will provide the lowest drift data conversion obtainable.
VRE104 series devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to +125°C, and two performance grades. All devices are packaged in 14-pin hermetic ceramic packages for maximum long-term stability. "M" versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make the VRE104 ideal for all precision applications which may require a 4.5V reference. High-accuracy test and measurement instrumentation, and transducer excitation are some other applications which can benefit from the high accuracy of the VRE104.