Features: • Patent Pending Integrated Thermal Protection Device• Designed to facilitate compliance to UL1449 for TVSS product• High peak surge current rating up to 10kA• Wave solderable• Standard lead form and spacing option• Low Leakage• -55°C to +85°C Op...
UL1449: Features: • Patent Pending Integrated Thermal Protection Device• Designed to facilitate compliance to UL1449 for TVSS product• High peak surge current rating up to 10kA• Wave...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Steady State Applied Voltage:
AC Voltage Range (VM(AC)RMS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 to 750 V
Transient:
Peak Pulse Current (ITM)
For 8x20s Current Wave, single pulse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6000 to 10,000 A
Single-Pulse Energy Capability
For 2ms Current Wave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 to 480 J
Operating Ambient Temperature Range (TA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55 to 85
Storage Temperature Range (TSTG). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 to 125
Temperature Coefficient (V) of Clamping Voltage (VC) at Specified Test Current . .<0.01 %/
Hi-Pot Encapsulation (Isolation Voltage Capability) . . . . . . . . . . . . . . . . . . . . . . . . 2500 V
Thermal Protection Isolation Voltage Capability (when operated) . . . . . . . . . . . . . . . . . .600 V
Insulation Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,000 M
Indicator Lead Rating (Lead-3 - iTMOV varistor only):
Continuous RMS current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 mA
Surge Current, 8/20s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10,000 A
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.