Features: ·Plastic package has Underwriters Laboratories Flammability Classification 94V-0·Ideally suited for freewheeling diode power factor correction applications ·Soft recovery characteristics·Excellent high temperature switching·Planar technology·Optimized to reduce switching losses·High temp...
UG8JT: Features: ·Plastic package has Underwriters Laboratories Flammability Classification 94V-0·Ideally suited for freewheeling diode power factor correction applications ·Soft recovery characteristics·E...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
SYMBOLS |
UGB10FCT |
UGB10GCT |
UNITS | |
Maximum repetitive peak reverse voltage |
VRRM |
500 |
600 |
Volts |
Working peak reverse voltage |
VRWM |
400 |
480 |
Volts |
Maximum RMS voltage |
VRMS |
350 |
420 |
Volts |
Maximum DC blocking voltage |
VDC |
500 |
500 |
Volts |
Maximum average forward rectified current at TC=105°C |
I(AV) |
8.0 |
Amps | |
Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method) per leg |
IFSM |
100.0 |
Amps | |
Maximum instantaneous forward voltage per leg IF=5A |
VF |
1.75 1.50 |
Volts | |
Maximum DC reverse current TC=25°C at rated DC blocking voltage per leg TC=100°C |
IR |
30 800 4.0 |
A | |
Maximum reverse recovery time |
trr |
25 |
ns | |
Maximum reverse recovery time TJ=25°C TJ=100°C |
trr |
50 35 |
ns | |
Typical softness factor (tb/ta) IF=8.0A, di/dt=240A/ms, VR=400V Irr=0.1 IRM |
IRM |
5.5 |
||
Maximum reverse recovery current per leg at IF=5A, di/dt=50A/ms,VR=30V TC=100°C |
IRM |
10.0 |
nC | |
Maximum stored charge per leg IF=8A, di/dt=240A/ms, VR=400V, |
tfr |
500 250 |
pF | |
Typical thermal resistance from junction to case per leg |
RQJC |
2.2 |
°C/W | |
Operating junction and storage temperature range |
TJ, TSTG |
-40 to +150 |
°C |