Features: · 10-W/Channel Into an 16-W Load From a 17-V Supply· Up to 92% Efficient, Class-D Operation Eliminates Need For Heatsinks· 8.5-V to 18-V Single-Supply Operation· Four Selectable, Fixed Gain Settings· Differential Inputs Minimizes Common-Mode Noise· Space-Saving, Thermally Enhanced PowerP...
TPA3008D2: Features: · 10-W/Channel Into an 16-W Load From a 17-V Supply· Up to 92% Efficient, Class-D Operation Eliminates Need For Heatsinks· 8.5-V to 18-V Single-Supply Operation· Four Selectable, Fixed Gai...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
TPA3008D2 | ||
Supply voltage range |
AVCC, PVCC |
-0.3 V to 20 V |
Load Impedance, RL |
6 | |
Input voltage range, VI |
SHUTDOWN |
-0.3 V to VCC + 0.3 V |
GAIN0, GAIN1, RINN, RINP, LINN, LINP |
-0.3 V to 6 V | |
Continuous total power dissipation |
See Dissipation Rating Table | |
Operating freeair temperature range, TA |
- 40°C to 85°C | |
Operating junction temperature range, TJ |
- 40°C to 150°C | |
Storage temperature range, Tstg |
- 65°C to 150°C | |
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds |
260°C |
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolutemaximumrated conditions for extended periods may affect device reliability.
The TPA3008D2 is a 10-W (per channel) efficient, class-D audio amplifier for driving bridged-tied stereo speakers. The TPA3008D2 can drive stereo speakers as low as 8 W. The high efficiency of the TPA3008D2 eliminates the need for external heatsinks when playing music.
The gain of the amplifier TPA3008D2 is controlled by two gain The gain selections are 15.3, 21.2, 27.2,Noise and 31.8 dB.
The outputs of TPA3008D2 are fully protected against shorts to GND, VCC, and output-to-output shorts. A fault ter- minal allows short-circuit fault reporting and automatic recovery. Thermal protection ensures that the maxi mum junction temperature is not exceeded.