Features: AC/DC Power Modules for PCB MountingHighest Power DensityFully encapsulated Plastic CaseUniversal Input 90-264 VAC, 47 - 440 HzHigh EfficiencyEMI meets EN 55022, Class BLow Ripple and NoiseShort Circuit and Overload Protection3 Year Product WarrantySpecifications Input voltage range...
TMLM10112: Features: AC/DC Power Modules for PCB MountingHighest Power DensityFully encapsulated Plastic CaseUniversal Input 90-264 VAC, 47 - 440 HzHigh EfficiencyEMI meets EN 55022, Class BLow Ripple and Nois...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
AC/DC Power Modules for PCB Mounting
Highest Power Density
Fully encapsulated Plastic Case
Universal Input 90-264 VAC, 47 - 440 Hz
High Efficiency
EMI meets EN 55022, Class B
Low Ripple and Noise
Short Circuit and Overload Protection
3 Year Product Warranty
Input voltage range | 90 264 VAC or 120 370 VDC | |
Input frequency | 47 440 Hz | |
Input current full load | 220 mA @ 115 VAC / 150 mA @ 230 VAC | |
External fuse (recommended) | 1.5 A slow blow type | |
Voltage set accuracy | ± 2 % | |
Regulation | Input variation Load variation (5 100%) |
0.3 % max. 0.5 % max. |
Minimum load | 0 % | |
Ripple and noise (20 MHz Bandwidth) | 3.3 & 5 VDC output models: other models: |
< 1.5 % of Vout < 1.0 % of Vout |
Over voltage protection | Zener diode clamp | |
Current limitation | > 120 % fold back | |
Short circuit protection | hiccup mode, indefinite (automatic recovery) | |
Maximum capacitive load | 10'000 µF | |
Temperature ranges | Operating Power derating above 50°C Storage (non operating) |
25 °C.+71 °C 3.75 %/°C 40 °C.+85 °C |
Temperature coefficient | 0.02 % / °C | |
Efficiency | 80 % (depending on model) | |
Humidity (non condensing) | 95 % rel max. | |
Switching frequency | 125 kHz typ. (Puls width modulation PWM) | |
Hold-up time | 15 ms min. | |
Isolation voltage | Input/ Output | 3'000 VAC |
Reliability /calculated MTBF (MIL-HDBK-217E) | t.b.a. | |
EMI / RFI conducted | EN 55022, class B | |
EMC compliance | Electrostatic discharge ESD RF field susceptibility Electrical fast transients / bursts on mainsline |
IEC / EN 61000-4-2 4 kV / 8 kV IEC / EN 61000-4-3 3 V/m IEC / EN 61000-4-4 1 kV |
Safety Class ll | to IEC / EN 60536 | |
Safety standards | UL 60950, IEC 60950, EN 60950 | |
Safety approval | cUL / UL File E188913 | |
Case material | Plastic resin + Fiberglass (UL 94V-0 - rated) |