PinoutSpecificationsSupply voltage, VCC (see Note 1). . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . .. . . . 20 V Input voltage range, VI:RESIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . .. . . 0.3 V to 20 V SENSE. . . . . . . . . . . . . ...
TL7705BQ: PinoutSpecificationsSupply voltage, VCC (see Note 1). . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . .. . . . 20 V Input voltage range, VI:RESIN. . . . . . . . . . . . ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
The TL7702B and TL7705B are integrated-circuit supply-voltage supervisors designed for use as reset controllers in microcomputer and microprocessor systems. The supply-voltage supervisor monitors the supply for undervoltage conditions at the SENSE input. During power up, the TL7702B and TL7705B RESET output becomes active (low) when VCC attains a value approaching 1 V. As VCC approaches 3 V (assuming that SENSE is above VT+), the delay timer function activates a time delay, after which outputsTL7702B and TL7705B RESET and RESET go inactive (high and low, respectively). When an undervoltage condition occurs during normal operation, outputs RESET and RESET go active. To ensure that a complete reset occurs, the reset outputs remain active for a time delay after the voltage at the SENSE input exceeds the positive-going threshold value. The time delay is determined by the value of the external capacitor CT: td 2.6 * 104 * CT, where CT is in farads (F) and td is in seconds (s).
An external capacitor (typically 0.1 µF) TL7702B and TL7705B must be connected to REF to reduce the influence of fast transients in the supply voltage.
The TL7702BC and TL7705BC are characterized for operation from 0°C to 70°C. The TL7702BI and TL7705BI are characterized for operation from 40°C to 85°C. The TL7705BQ is characterized for operation from 40°C to 125°C. The TL7705BM is characterized for operation from 55°C to 125°C.