Features: ` Simple Voltage Conversion, Including Negative Converter Voltage Doubler` Wide Operating Range¼1.5 V to 10 V` Requires Only Two External (Noncritical)Capacitors` No External Diode Over Full Temperature and Voltage Range` Typical Open-Circuit Voltage Conversion Efficiency¼9...
TL7660: Features: ` Simple Voltage Conversion, Including Negative Converter Voltage Doubler` Wide Operating Range¼1.5 V to 10 V` Requires Only Two External (Noncritical)Capacitors` No External Diode ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Features: · Qualified for Automotive Applications· ±3% Output Voltage Variation Across Load and Te...
Features: · Qualified for Automotive Applications· ±3% Output Voltage Variation Across Load and Te...
Features: · Qualified for Automotive Applications· ±3% Output Voltage Variation Across Load and Te...
MIN | MAX | UNIT | ||
VCC Supply voltage | TL7660 | 10.5 | V | |
VI OSC and LV input voltage range(2) | VCC < 5.5 V VCC > 5.5 V |
0.3 VCC 5.5 |
VCC + 0.3 VCC + 0.3 |
V |
tOS Output short-circuit duration | VCC > 3.5 V VSUPPLY ± 5.5 V |
20 Continuous |
A | |
JA Package thermal impedance(3) (4) | D package DGK package P package |
97 172 85 |
/W | |
TJ Junction temperature Tstg Storage temperature range |
-55 |
150 150 |
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other onditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Connecting any input terminal to voltages greater than VCC or less than GND may cause destructive latchup. It is recommended that no inputs from sources operating from external supplies be applied rior to power up of the TL7660.
(3) Maximum power dissipation is a function of TJ(max), JA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) TA)/JA. Operating at the absolute maximum TJ of 150 can affect reliability.
(4) The package thermal impedance is calculated in accordance with ESD 51-7.
The TL7660 is a CMOS switched-capacitor voltage converter that perform supply-voltage conversions from positive to negative. With only two noncritical external capacitors needed for the charge pump and charge reservoir functions, an input voltage within the range from 1.5 V to 10 V is converted to a complementary negative output voltage of 1.5 V to 10 V. The device can also be connected as a voltage doubler to generate output voltages up to 18.6 V with a 10-V input.
The TL7660 basic building blocks of the IC include a linear regulator, an RC oscillator, a voltage-level translator, and four power MOS switches. To ensure latch-up-free operation, the circuitry automatically senses the most negative voltage in the device and ensures that the N-channel switch source-substrate junctions are not forward biased. The oscillator frequency runs at a nominal 10 kHz (for VCC = 5 V), but that frequency can be decreased by adding an external capacitor to the oscillator (OSC) terminal or increased by overdriving OSC with an external clock.
For low-voltage operation (VIN < 3.5 V), LV should be tied to GND to bypass the internal series regulator. Above 3.5 V, LV should be left floating to prevent device latchup.
The TL7660C is characterized for operation over a free-air temperature range of 40 to 85. The TL7660I is characterized for operation over a free-air temperature range of 40 to 125.