SpecificationsSupply voltage: VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 V VCC− (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .−18 V VCC+ with respect to VCC− . . . . . . . . . . . . . . . . . . . ...
TL092: SpecificationsSupply voltage: VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 V VCC− (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
US $.22 - .26 / Piece
Operational Amplifiers - Op Amps JFET-input Oper Amplifier
Supply voltage: VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 V
VCC− (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .−18 V
VCC+ with respect to VCC− . . . . . . . . . . . . . . . . . . . . . . . . .. .. . . .36 V
Differential input voltage, VID (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . .±36 V
Input voltage, VI (see Notes 1 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±18 V
Package thermal impedance, JA (see Notes 4 and 5) . . . . . . . . . . . . . .. . . . .95°C/W
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . .260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . .−65°C to 150°C
The TL092 JFET-input operational amplifier is similar in performance to the MC3403 family, but with much higher input impedance derived from a FET input stage. The N-channel-JFET input stage allows a common-mode input voltage range that includes the negative supply voltage and offers a typical input impedance of 1012 Ω a typical input offset current of 50 pA, and a typical input bias current of 200 pA. This device is designed to operate from a single supply over a range of 3 V to 36 V. Operation from split supplies also is possible, provided the difference between the two supplies is 3 V to 36 V. Output voltage range is from VCC− to VCC+ − 1.3 V, with a load resistor to VCC−.
The TL092 is characterized for operation from 0°C to 70°C.