Sidacs
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
PinoutSpecifications Rating Symbol Value Unit Repetitive peak off-state voltage...
PinoutSpecifications RATING SYMBOL VALUE UNIT Repetitive peak off-state voltage ( 0°C &...
Breakover Voltage VBO : | +/- 395 V | Breakover Current IBO Max : | +/- 600 mA | ||
Non Repetitive On-State Current : | 50 A | Rated Repetitive Off-State Voltage VDRM : | +/- 320 V | ||
Off-State Leakage Current @ VDRM IDRM : | +/- 5 uA | Holding Current (Ih Max) : | +/- 600 mA | ||
Off-State Capacitance CO : | 35 pF to 105 pF | Maximum Operating Temperature : | + 85 C | ||
Mounting Style : | SMD/SMT | Package / Case : | DO-214AA-2 |
Rating |
Symbol |
Value |
Unit |
Repetitive peak off-state voltage '4290 '4350 '4395 |
VDRM |
|
V |
Non-repetitive peak on-state pulse current (see Notes 1 and 2) 2/10 (Telcordia GR-1089-CORE, 2/10 voltage wave shape) 8/20 (IEC 61000-4-5, combination wave generator, 1.2/50 voltage wave shape) 10/160 (TIA-968-A (Replaces FCC Part 68), 10/160 voltage wave shape) 4/250 (ITU-T K.20/21, 10/700 voltage wave shape, simultaneous) 5/310 (ITU-T K.20/21, 10/700 voltage wave shape, single) 5/320 (TIA-968-A (Replaces FCC Part 68), 9/720 voltage wave shape, single) 10/560 (TIA-968-A (Replaces FCC Part 68), 10/560 voltage wave shape) 10/1000 (Telcordia GR-1089-CORE, 10/1000 voltage wave shape) |
IPPSM |
1000 800 400 370 350 350 250 200 |
A |
Non-repetitive peak on-state current (see Notes 1 and 2) 50 Hz, 1 cycle 60 Hz, 1 cycle |
ITSM |
80 100 |
A |
Initial rate of rise of on-state current, Linear current ramp, Maximum ramp value < 50 A |
diT/dt |
800 |
A/s |
Junction temperature |
TJ |
-40 to +150 |
°C |
Storage temperature range |
Tstg |
-65 to +150 |
°C |
The range of TISP4xxxJ3BJ devices are designed to limit overvoltages on telecom lines. The TISP4xxxJ3BJ is primarily designed to address GR-1089-CORE compliance on data transmission lines with d.c. power feeding. When overvoltage protection is applied to transformer coupled lines from the transformer center tap to ground, the total ground return current can be 200 A, 10/1000 and 1000 A, 2/10. The high 150 mA holding current is set above common d.c. feed system levels to allow the TISP4xxxJ3BJ to reset following a disturbance.
These devices TISP4xxxJ3BJ allow signal voltages, without clipping, up to the maximum off-state voltage value, VDRM, see Figure 1. Voltages above VDRM are limited and will not exceed the breakover voltage, V(BO), level. If sufficient current flows due to the overvoltage, the device switches into a low voltage on-state condition, which diverts the current from the overvoltage through the device. When the diverted current falls below the holding current, IH, level the devices switches off and restores normal system operation.