Features: Simultaneous Sampling of 4 Single-Ended Signals or 2 Differential Signals or Combination of Both Signal-to-Noise and Distortion Ratio: 59 dB at fI = 2 MHz Differential Nonlinearity Error: ±1 LSB Integral Nonlinearity Error: ±1 LSB Auto-Scan Mode for 2, 3, or 4 Inputs 3-V or 5-V Digital I...
THS1007: Features: Simultaneous Sampling of 4 Single-Ended Signals or 2 Differential Signals or Combination of Both Signal-to-Noise and Distortion Ratio: 59 dB at fI = 2 MHz Differential Nonlinearity Error: ...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
US $6.07 - 7.48 / Piece
ADC (A/D Converters) 10-Bit 6 MSPS Quad Ch DSP/uP Ifc
UNITS | ||
Supply voltage range | DGND to DVDD |
0.3 V to 6.5 V |
BGND to BVDD |
0.3 V to 6.5 V | |
AGND to AVDD |
0.3 V to 6.5 V | |
Analog input voltage range |
AGND 0.3 V to AVDD + 1.5 V | |
Reference input voltage |
0.3 V + AGND to AVDD + 0.3 V | |
Digital input voltage range |
0.3 V to BVDD/DVDD + 0.3 V | |
Operating virtual junction temperature range, TJ |
40°C to 150°C | |
Operating free air temperature range TA | THS1007C |
0°C to 70°C |
THS1007I |
30°C to 85°C | |
Storage temperature range, Tstg |
65°C to 150°C | |
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds |
260°C |
The THS1007 is a CMOS, low-power, 10-bit, 6 MSPS analog-to-digital converter (ADC). The speed, resolution, bandwidth, and single-supply operation of THS1007 are suited for applications in radar, imaging, high-speed acquisition, and communications. A multistage pipelined architecture with output error correction logic provides for no missing codes over the full operating temperature range. Internal control registers are used to program the ADC into the desired mode. The THS1007 consists of four analog inputs, which are sampled simultaneously. These inputs can be selected individually and configured to single-ended or differential inputs. Internal reference voltages for the ADC (1.5 V and 3.5 V) are provided. An external reference can also be chosen to suit the dc accuracy and temperature drift requirements of the application.
The THS1007C is characterized for operation from 0°C to 70°C, and the THS1007I is characterized for operation from 40°C to 85°C.