TGA4600-EPU

Features: ·Typical Frequency Range:57-65 GHz·4 dB Nominal Noise Figure·13 dB Nominal Gain·Bias 3.0 V, 41 mA·0.15 um 3MI pHEMT Technology·Chip Dimensions 1.62 × 0.84 × 0.10 mm (0.064 × 0.033 × 0.004 in)Application·Wireless LAN·Point-to-Point RadioSpecifications SYMBOL PARAMETER VALUE ...

product image

TGA4600-EPU Picture
SeekIC No. : 004518378 Detail

TGA4600-EPU: Features: ·Typical Frequency Range:57-65 GHz·4 dB Nominal Noise Figure·13 dB Nominal Gain·Bias 3.0 V, 41 mA·0.15 um 3MI pHEMT Technology·Chip Dimensions 1.62 × 0.84 × 0.10 mm (0.064 × 0.033 × 0.004 ...

floor Price/Ceiling Price

Part Number:
TGA4600-EPU
Supply Ability:
5000

Price Break

  • Qty
  • 1~5000
  • Unit Price
  • Negotiable
  • Processing time
  • 15 Days
Total Cost: $ 0.00

SeekIC Buyer Protection PLUS - newly updated for 2013!

  • Escrow Protection.
  • Guaranteed refunds.
  • Secure payments.
  • Learn more >>

Month Sales

268 Transactions

Rating

evaluate  (4.8 stars)

Upload time: 2025/1/12

Payment Methods

All payment methods are secure and covered by SeekIC Buyer Protection PLUS.

Notice: When you place an order, your payment is made to SeekIC and not to your seller. SeekIC only pays the seller after confirming you have received your order. We will also never share your payment details with your seller.
Product Details

Description



Features:

·Typical Frequency Range:57-65 GHz
·4 dB Nominal Noise Figure
·13 dB Nominal Gain
·Bias 3.0 V, 41 mA
·0.15 um 3MI pHEMT Technology
·Chip Dimensions 1.62 × 0.84  × 0.10 mm  (0.064 × 0.033 × 0.004 in)



Application

·Wireless LAN
·Point-to-Point Radio



Specifications

SYMBOL
PARAMETER
VALUE
NOTES
Vd
Drain Voltage
5V
2/
Vg
Gate Voltage Range
-1 TO +0.5 V
Id
Drain Current
200 mA
2/3/
|Ig|
Gate Current
5 mA
3/
PIN
Input Continuous Wave Power
15 dBm
PD
Power Dissipation
0.39W
2/4/
TCH
Operating Channel Temperature
150
5/6/
TM
Mounting Temperature (30 Seconds)
320
TSTG
Storage Temperature
-65 to 150

` These ratings represent the maximum operable values for this device.
`Combinations of supply voltage, supply current, input power, and output power shall not exceed PD.
`Total current for the entire MMIC.
` When operated at this bias condition with a base plate temperature of 70, the median life is 1.0E+6 hrs.
` Junction operating temperature will directly affect the device median time to failure (MTTF).  For maximum life, it is recommended that junction temperatures be maintained at the lowest possible levels.
` These ratings apply to each individual FET.