Features: • Minimum wiring complexity• Overtemperature protection without external components• Malfunction detection• Timer output• Automatical re-ignition after lamp changeSpecifications Pin Symbol min max unit current consumptionpeak current for t&...
TFA3354: Features: • Minimum wiring complexity• Overtemperature protection without external components• Malfunction detection• Timer output• Automatical re-ignition after lamp c...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Pin | Symbol | min | max | unit | |
current consumption peak current for t< 100 µs input voltage error indicator input voltage lamp exchange input voltage difference between VLW and VCC for divider factor 16 via LW input current at pin TM negative current load for t<1µs with max. repeat frequency = 200kHz switching output current junction temperature storage temperature ambient temperature ESD protection |
VCC VCC EI LW LW TM TR S |
ICCeff ICCM VErr VLW VLW - VCC ITM ITR(neg.) IS Tj Tstg Tamb VESD |
-0.3 -0.3 -500 -50 -20 |
20 100 VCC 15 6 1 1 150 150 120 2 |
mA mA V V V mA mA mA °C °C °C kV |
The bipolar monolithic integrated circuit TFA3354 triggers, monitors and turns-off RF-oscillation of an electronic ballast for fluorescent lamps dependent on several control- and monitoring functions.