Application· Primart rate ISDN network nodes.· PBX or computer to T1/CEPT Digital trunk· TDM MultiplexersPinoutDescriptionTEW5315 is designed to be used either as a transmit or a receive transformer in the ISDN primary access network, interfacing the SIEMENS PEB2235 to a 75, 100 or 120 ohm line. W...
TEW5315: Application· Primart rate ISDN network nodes.· PBX or computer to T1/CEPT Digital trunk· TDM MultiplexersPinoutDescriptionTEW5315 is designed to be used either as a transmit or a receive transformer...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
TEW5315 is designed to be used either as a transmit or a receive transformer in the ISDN primary access network, interfacing the SIEMENS PEB2235 to a 75, 100 or 120 ohm line.
When in transmit mode, connect the two primary windings in parallel, pin 3 to 4 and pin 6 to 5.
When in receive mode, connect the two primary windings in series, pin 6 to pin 4, thus forming a center tap at pin 6/4.