Features: • Temperature Proportional Fan Speed for Reduced Acoustic Noise and Longer Fan Life• FanSense™ Protects against Fan Failure and Eliminates the Need for 3-wire Fans• Over Temperature Detection (TC665)• Efficient PWM Fan Drive• Provides RPM Data• 2...
TC665: Features: • Temperature Proportional Fan Speed for Reduced Acoustic Noise and Longer Fan Life• FanSense™ Protects against Fan Failure and Eliminates the Need for 3-wire Fans•...
SeekIC Buyer Protection PLUS - newly updated for 2013!
268 Transactions
All payment methods are secure and covered by SeekIC Buyer Protection PLUS.
Parameter Name | Value |
Typical Accuracy (°C) | Depends on external thermistor |
Over Temp Alert | yes |
SM Bus | yes |
Predictive Fan Fault | yes |
Max. Supply Current (A) | 320 |
Max. Accuracy @ 25°C (°C) | Depends on external thermistor |
Integrated Temp Sensor | No |
Fan Sense | Yes |
External Temp Input | Yes |
Auto Shutdown | No |
Device Description | Single SMBus Fan Manager |
Temp Range (°C) | -40 to +85 |
Vcc Range (V) | +3.0 to +5.5 |
VDD......................................................................................6.5 V
Input Voltages ....................................... -0.3 V to (VDD + 0.3 V)
Output Voltages .................................... -0.3 V to (VDD + 0.3 V)
Storage temperature .....................................-65°C to +150°C
Ambient temp. with power applied ................-40°C to +125°C
Maximum Junction Temperature, TJ ................................. 150°C
ESD protection on all pins.................................................. 4 kV
*Notice: Stresses above those listed under "Maximum ratings"
may cause permanent damage to the device. This is a
stress rating only and functional operation of the device at
those or any other conditions above those indicated in the
operational listings of this specification is not implied. Exposure
to maximum rating conditions for extended periods may
affect device reliability.
In normal fan operation, pulse trains are present at the SENSE pin. These pulses are used to calculate the fan RPM. The fan RPM data is used to detect a worn out, stalled, open or unconnected fan. An RPM level below the user-programmable threshold causes the TC665 to assert a logic low alert signal (FAULT). Thedefault value is 500RPM. The TC665 consumes only 0.3mA during operation and can also enter a low-power shutdown mode by setting the appropriate bit in the configuration register.